PubMed · 10899628
Enzyme activity down to -100 degrees C.
Abstract
The activities of two enzymes, beef liver catalase (EC 1.11.1.6) and calf intestine alkaline phosphatase (EC 3.1.3.1), have been measured down to -97 degrees C and -100 degrees C, respectively. Enzyme activity has not previously been measured at such low temperatures. For catalase, the cryosolvents used were methanol:ethylene glycol:water (70:10:20) and DMSO:ethylene glycol:water (60:20:20). For alkaline phosphatase, methanol:ethylene glycol:water (70:10:20) was used. All of the Arrhenius plots were linear over the whole of the temperature range examined. Since the lowest temperatures at which activity was measured are well below the dynamic transition observed for proteins, the results indicate that the motions which cease below the dynamic transition are not essential for enzyme activity. In all cases the use of cryosolvent led to substantial increases in Arrhenius activation energies, and this imposed practical limitations on the measurement of enzyme activity below -100 degrees C. At even lower temperatures, enzyme activity may be limited by the effect of solvent fluidity on substrate/product diffusion, but overall there is no evidence that any intrinsic enzyme property imposes a lower temperature limit for enzyme activity.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J M Bragger, R V Dunn, R M Daniel. 2000-07-14. Enzyme activity down to -100 degrees C.. https://doi.org/10.1016/s0167-4838(00)00081-9
Cite the original work for its findings. Save a collection to share your selection of sources.