PubMed Health⌕ Search

PubMed · 10912341

A spot check for estimating stereophotogrammetric errors.

Abstract

Good practice rules in the management of a movement analysis laboratory recommend that photogrammetric measurement errors are assessed, prior to every experimental session, using an ad hoc experiment referred to as a spot check. The paper proposes an inexpensive and easy to make spot check. The test uses a rigid rod carrying two markers and a target point taken on the line joining them and coinciding with the rod tip. The latter point is placed in a fixed and measured position in the laboratory frame and the markers are tracked while the rod is kept stationary and while it is manually made to rotate about the target point. Several target points are used within the measurement volume. The instantaneous errors with which the laboratory co-ordinates of the latter points are reconstructed are determined and submitted to statistical analysis. A normalisation procedure is illustrated that aims at making the test results independent from the geometry of the test object. The experimental and analytical methods underlying the proposed spot check were validated experimentally in two movement analysis laboratories using repeated tests. A rod, 1.5 m long, carrying four markers was used. In this way, several test-object geometries were tested. Results confirmed that the photogrammetric error could be divided into a zero-mean random and a systematic component. It was shown that the normalisation procedure was effective for the standard deviation of both error components when the two markers were located at a distance between them 1.5 times larger than the distance of their centroid from the tip of the rod. The systematic component bias could not be normalised, however a conservative value of it could be estimated. The two above-mentioned normalised standard deviations and the bias value can be taken as descriptors of the photogrammetric error of the specific measuring system tested. These parameters may also be used to assess the precision and the accuracy with which the laboratory position of a target point, defined relative to any specified marker cluster, may be reconstructed during movement analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Della Croce, A Cappozzo. 2000. A spot check for estimating stereophotogrammetric errors.. https://doi.org/10.1007/bf02347045

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Global Genomic Surveillance.

Global genomic surveillance has emerged as a foundational pillar of public health in the twenty-first century, enabling real-time tracking of pathogen evolution and informing outbreak response. This chapter examines the strategic architecture of global genomic surveillance, focusing on its application to arboviruses such as chikungunya virus (CHIKV). It explores the integration of genomic data with epidemiological, clinical, and environmental information within a One Health framework, while addressing critical challenges in governance, equity, and interoperability. The discussion covers the entire genomic surveillance workflow, from sample collection and sequencing to bioinformatic analysis and phylogenetic inference, and highlights the transformative role of artificial intelligence (AI) in predictive surveillance. By analyzing global initiatives, operational barriers, and emerging technologies, this chapter underscores the necessity of sustainable, equitable, and interoperable genomic systems to proactively address current and future infectious disease threats.

Humans↗

Systematic Dissection of Key Driver Perturbation Signatures in Single Cells via ECCITE-seq.

CRISPR screens, such as expanded CRISPR-compatible cellular indexing of transcriptomes and epitopes by sequencing (ECCITE-seq), enable the simultaneous measurement of transcriptomes, gRNA identity, and cell-surface protein expression at single-cell resolution to systematically interrogate gene function. This platform provides a powerful and scalable experimental approach for validating disease-associated regulators identified by large-scale association studies and other computational methods, including network-based analyses of multi-omics data. Here, as an example application, we describe an ECCITE-seq framework to characterize the transcriptomic consequences of perturbing multiple neuronal key driver genes associated with Alzheimer's disease (AD) in human-induced pluripotent stem cell (hiPSC)-derived neurons. More broadly, by integrating customized pooled gRNA libraries with different CRISPR effectors across multiple cell types, this approach allows for the assessment of the regulatory impact of candidate genes implicated in development and disease processes.

Humans↗

Identification of Genome-Wide Chromatin Structural Aberration in Cancer by Hi-C Analysis.

Aberrant three-dimensional genome organization is a hallmark of cancer, often driving oncogene activation through mechanisms such as enhancer hijacking. High-throughput chromosome conformation capture (Hi-C) maps these interactions on a genome-wide scale. Unlike earlier dilution-based methods, in situ Hi-C performs proximity ligation within intact nuclei, minimizing random ligation noise and enabling fine-scale structure detection. This chapter describes an optimized in situ Hi-C protocol tailored for cancer cell lines using MboI digestion and biotin-mediated pull-down to generate high-complexity libraries. We further outline a computational workflow that extends beyond standard topological mapping of compartments and topologically associating domains to identify cancer-specific aberrations. Specifically, we focus on detecting chromosomal rearrangements (structural variants) and characterizing the distinct circular topology of extrachromosomal DNA. This integrated experimental and analytical framework provides the necessary tools to dissect the spatial dysregulation underlying tumor evolution.

Humans↗