PubMed Health⌕ Search

PubMed · 10912347

An alpha modulation index for electroencephalographic studies using complex demodulation.

Abstract

An automated technique for measuring the relative amount of amplitude modulation of electroencephalographic (EEG) alpha activity is developed to increase the number of existing tools for differentiating the various types of alpha activity. EEG data collected from 12 normal males is used to characterize alpha modulation frequency characteristics. From these findings, a complex demodulation method is constructed to extract the amplitude modulation envelope of alpha activity from an epoch of EEG data while disregarding both continuous amplitude alpha activity and activity outside the alpha band. A threshold technique is then used to determine the relative amount of modulation contained within the data epoch. This metric is termed the alpha modulation index (AMI). Good correlation (R2 = 0.86) is found when automated scoring results are compared with manual scoring of physiologic EEG alpha modulation. The flexibility of this technique makes it easily adaptable to other EEG frequency bands and applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Schroeder, R E Barr. 2000. An alpha modulation index for electroencephalographic studies using complex demodulation.. https://doi.org/10.1007/bf02347051

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The distinction between eye and object motion is reflected by the motion-onset visual evoked potential.

Humans are able to distinguish eye movement-induced retinal image motion and physical object motion during smooth pursuit eye movements. We investigated the neurophysiological basis of this ability by comparing motion-onset visual evoked potentials (VEPs) to onset of: (1) physical object motion during fixation, (2) eye movement-induced retinal image motion, and (3) physical object motion during eye movements. Electro-oculographic (EOG) artifacts were removed and the influence of eye-movement quality was evaluated. Retinal image shift was of similar magnitude in all conditions (9 degrees /s) and elicited typical motion-onset VEPs, with N2 at occipital and P2 at central derivations. During smooth pursuit, physical object motion induced N2 and P2 of higher latencies than during fixation. In the absence of physical object motion, i.e., for exclusively eye movement-induced retinal image motion, the N2 amplitude was reduced. This is taken as evidence that the activity of detectors of physical object motion is reflected by a part of the N2 component. N2 also reflects eye movement-induced retinal image motion. It is concluded that headcentric motion detection and the detection of eye movement-induced retinal image motion is mediated by brain mechanisms with similar latencies and, within the resolution limits of VEPs, at similar locations.

Electroencephalography↗

Correlation-dimension and autocorrelation fluctuations in epileptic seizure dynamics.

We focus on an anomalous scaling region in correlation integral [C(epsilon)] analysis of electrocorticogram in epilepsy patients. We find that epileptic seizures typically are accompanied by wide fluctuations in the slope of this scaling region. An explanation, based on analyzing the interplay between the autocorrelation and C(epsilon), is provided for these fluctuations. This anomalous slope appears to be a sensitive measure for tracking (but not predicting) seizures.

Electroencephalography↗