PubMed Health⌕ Search

PubMed · 10913718

A model system for perfusion quantification using FAIR.

Abstract

Flow-sensitive experiments (FAIR) have been performed on a tube-flow phantom in order to validate quantitative perfusion measurements on humans. A straight-forward correspondence between perfusion and bulk-flow is found. It is shown that the flow phantom model only holds when the slice profiles of the involved RF pulses are taken into account. A small flow-independent off-set may be present in the data. The off-set is explained by the model. Based on the correspondence between the phantom and the in vivo models, it is shown that the lowest flow values that could be measured in the phantom correspond to perfusion values lower than the cortical perfusion in the brain. Thus, the experimental accuracy and the computational methods for quantitative perfusion measurements in vivo can be validated by a tube-flow phantom.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I K Andersen, K Sidaros, H Gesmara, E Rostrup, H B Larsson. 2000. A model system for perfusion quantification using FAIR.. https://doi.org/10.1016/s0730-725x(00)00136-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simple anatomical measurements do not correlate significantly to individual peripheral nerve stimulation thresholds as measured in MRI gradient coils.

PURPOSE: To examine peripheral nerve stimulation (PNS) thresholds for normal human subjects in magnetic resonance imaging (MRI) gradient coils, and determine if observed thresholds could be predicted based on gross physiologic measurements. MATERIALS AND METHODS: PNS thresholds for 21 healthy normal subjects were measured using a whole-body gradient coil. Subjects were exposed to a trapezoidal echo-planar imaging (EPI) gradient waveform and the total change in gradient strength (DeltaG) required to cause PNS as a function of the duration of the gradient switching time (tau) were measured. Correlation coefficients and corresponding P values were calculated for the PNS threshold measurements against simple physiologic measurements taken of the subjects, including weight, height, girth, and average body fat percentage, in order to determine if there were any easily observable dependencies. RESULTS: No convincing correlations between threshold parameters and gross physiologic measurements were observed. CONCLUSION: These results suggest it is unlikely that a simple physiologic measurement of subject anatomy can be used to guide the operation of MRI scanners in a subject-specific manner in order to increase gradient system performance while avoiding PNS.

Echo-Planar Imaging↗

Quantitative imaging of magnetization transfer using an inversion recovery sequence.

A new imaging method has been developed for quantitatively measuring magnetization transfer (MT). It uses a simple inversion recovery sequence, although one with very short (milliseconds) inversion times, and thus can be implemented on clinical imaging systems with little modification to existing pulse sequences. The sequence requires an inversion pulse with a length much longer than T(2m) (typically 10 micros) and much shorter than T(2f) (typically tens of ms) and 1/k(mf) (typically tens of ms), where T(2m) and T(2f) are the transverse relaxation times of the immobile macromolecular and free water protons, respectively, and k(mf) is the rate of MT between these populations. The resultant NMR signal is sensitive to MT when this inversion pulse affects the mobile and immobile proton pools to different degrees and by appropriate analysis of the signals obtained for different inversion times, quantitative information can be derived on the macromolecular content and exchange rates within the sample. The method has been used in conjunction with echo planar imaging to produce maps of the spatial distribution of the macromolecular content and MT rate in cross-linked bovine serum albumin. Comparisons between this method and other quantitative MT techniques are discussed.

Echo-Planar Imaging↗