Trigger for platelet transfusion.

Abstract

BACKGROUND AND OBJECTIVES: The terms 'platelet transfusion trigger' are used in the scientific literature to indicate a value of the platelet count above which prophylactic platelet transfusion is usually not indicated. Most clinicians share the currently prevalent consensus published in several guidelines that a platelet transfusion trigger of 10,000 platelets per microliter is safe in stable oncohematology recipients carefully monitored at both the clinical and laboratory levels, whereas higher values may be necessary in patients with high fever, infection, splenomegaly, rapid platelet count decrease, on drugs able to affect platelet function and survival, in cases undergoing invasive maneuvers and in some pediatric patients such as premature newborns. The safety of this policy is supported by the results obtained in several randomized clinical trials and prolonged observational studies. Lowering the platelet transfusion trigger from the traditional value set at 20,000 platelets per microliter to the currently recommended value of 10,000 per microliter further stresses the importance of high-quality, sufficient and prompt platelet availability and close cooperation between clinicians and blood transfusion specialists. Furthermore, it requires a clear understanding of the discriminatory power of current automated hematology counters at very low platelet counts. In the surgical setting, where randomized clinical trials on the most appropriate platelet transfusion trigger are largely missing, current guidelines propose to maintain higher platelet count values (50,000-100,000 per microliter) during surgery and in the early postoperative period.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Rebulla. 2000. Trigger for platelet transfusion.. https://pubmed.ncbi.nlm.nih.gov/10938948/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[The measurement of immature reticulocyte fractions and clinical significance].

We evaluated automated analysis for the measurement of immature reticulocyte fraction(IRF) in 222 blood samples. IRF was performed by R-3000 & XE-2100(Sysmex), VEGA RETIC LC141(Horiba), ADVIA 120(Bayer medical), CELL DYN4000(Abbott) or GEN'S(Coulter), and compared with measurements obtained by visual counting. A subfraction of IRF was also determined using different modalities on all analyzers. The values of IRF were stable after blood storage for 48 hours at 4 degrees C and 8 hours at room temperature. A good correlation of IRF among these analyzers was obtained(r = 0.629-0.869), but the normal ranges in the percentage of IRF varied according to analyzers. However, an elevation in the percentage of IRF is the first sign of bone marrow recovery after chemotherapy and the bone marrow transplantation in the majority of leukemic patients. We suggest that IRF counting is useful for the estimation of early phase erythropoiesis in patients who have successful bone marrow engraftment following bone marrow transplantation.

Hematologic Diseases↗