Ion-pair solid-phase extraction.

Abstract

Solid-phase extraction (SPE) is a technique widely employed by analytical chemists. SPE cartridges are available in a wide variety of formats containing media with diverse chemistries. This paper will review ion-pair SPE, one of the less frequently applied, and presumably less well-known techniques. Advantages of this technique over more conventional reversed-phase or ion-exchange SPE include selectivity, compatibility with rapid evaporative concentration, and potential application to multiclass multiresidue analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M C Carson. 2000-07-14. Ion-pair solid-phase extraction.. https://doi.org/10.1016/s0021-9673(00)00471-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Colicin S8 export: extracellular and cytoplasmic colicin are different.

The properties of colicin S8 are different for the cytoplasmic, periplasmic and extracellular protein. Interactions with its specific receptors reflect this. Active cell extracts separate into a non-anionic along with an anionic fraction by DEAE-Sephacell chromatography. Previously, we have purified cell-associated colicin S8 as an aggregation of highly related polypeptides; cytoplasmic colicin S8 seems to be post-translationally processed into an aggregation of polypeptides of molecular mass ranging from 45,000 Da to 60,000 Da. We suggest that a conformational change to colicin S8 may occur related to the export process.

Chromatography, Ion Exchange↗

Transfer of gradient chromatographic methods for protein separation to Convective Interaction Media monolithic columns.

Convective Interaction Media (CIM) columns are monolithic columns optimized for the separation of macromolecules. Some of them operate in the axial mode while others operate in the radial mode depending on the column size. In this work we tested the approach suggested by Yamamoto [Biotechnol. Bioeng., 48 (1995) 444] for transfer of gradient methods between columns of different size. A simplified equation for transfer was derived together with a criterion for its application. Separation was evaluated for a standard protein mixture and peroxidase enzymes present in fermentation broth. Salt and pH gradients were applied. Similar resolutions were obtained for each sample on all columns which demonstrates that the proposed approach can be successfully used for method scale-up on this type of column.

Chromatography, Ion Exchange↗

Adsorption and isotope effects by ion exchange with 1-aza-12-crown-4 bonded Merrifield peptide resin.

Magnesium isotope effects were investigated by chemical ion exchange with synthesized 1-aza-12-crown-4 bonded Merrifield peptide resin using elution chromatography. The capacity of azacrown ion exchanger was 0.89 meq/g dry resin. The heavier isotopes of magnesium were enriched in the resin phase, while the lighter isotopes were enriched in the solution phase. The hydration effect is less than the complexation and isotope mass effects. The single stage separation factor was determined according to the method of Glueckauf from the elution curve and isotopic assays. The separation factors of 24Mg(2+)-25Mg(2+), 24Mg(2+)-26Mg(2+), and 25Mg(2+)-26Mg(2+) were 1.012, 1.023, and 1.011, respectively.

Chromatography, Ion Exchange↗