PubMed Health⌕ Search

PubMed · 10942991

Simulation of human gait using computed torque control.

Abstract

This paper presents a method for the mathematical modeling of both the single and double support phases of the human gait. The governing equations are obtained by considering the linkage model to be in a floating state and the foot-ground interaction is imposed in the form of geometric constraints. Two stages for the single support phase and one stage for the double support phase are considered, each described by a different foot-ground constraint. Feedback controller functioning according to the computed torque control method is used to achieve the normal gait described by the hip and ankle trajectories. Weighted least square optimization is used to solve the redundancy of control torques during the double support phase. The geometric simulation indicates that the imposed trajectories can be realized by the proposed model with some deviations in joint motions. The control strategy is tested by artificially perturbing the trajectories. The corrective actions are able to resume the desired pattern within half cycle, but with control torque magnitudes considerably away from reasonable limits. This is attributed to the insufficiency of the planar kinematic model and the assumption that the joint torques are unbounded.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N F Unver, S T Tümer, M K Ozgören. 2000. Simulation of human gait using computed torque control.. https://pubmed.ncbi.nlm.nih.gov/10942991/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element analysis of a total ankle replacement during the stance phase of gait.

Total ankle replacement (TAR) designs have still several important issues to be addressed before the treatment becomes fully acceptable clinically. Very little is known about the performance, in terms of the contact pressures and kinematics of TAR when subjected to daily activities such as level gait. For this purpose, an explicit finite element model of a novel 3-component TAR was developed, which incorporated a previously validated mechanical model of the ankle ligament apparatus. The intermediate mobile polyethylene meniscal bearing was modelled as an elastic-plastic continuum while the articulating surfaces of the tibial and talar metal components as rigid bodies. Overall kinematics, contact pressures and ligament forces were analysed during passive, i.e. virtually unloaded, and active, i.e. stance phase of gait, conditions. Simulation of passive motion predicted similar kinematics as reported previously in an analytical four-bar linkage model. The meniscal bearing was observed to move 5.6 mm posteriorly during the simulated stance and the corresponding antero-posterior displacement of the talar component was 8.3 mm. The predicted pattern and the amount (10.6 degrees ) of internal-external rotation of the ankle complex were found to be in good agreement with corresponding in vivo measurements on normal ankles. A peak contact pressure of 16.8 MPa was observed, with majority of contact pressures below 10 MPa. For most ligaments, reaction forces remain within corresponding physiological ranges. A first realistic representation of the biomechanical behaviour of the human ankle when replaced by prosthetic joints is provided. The applied methodology can potentially be applied to other TAR designs.

Ankle Joint↗

Contact stress transients during functional loading of ankle stepoff incongruities.

Cartilage deformation demonstrates viscoelastic behavior due to its unique structure. However, nearly all contact studies investigating incongruity-associated changes in cartilage surface stresses have been static tests. These tests have consistently measured only modest increases in contact stresses, even with large incongruities. In this study, an experimental approach measuring real-time contact stresses in human cadaveric ankles during quasi-physiologic motion and loading was used to determine how stepoff incongruities of the distal tibia affected contact stresses and contact stress gradients. Peak instantaneous contact stresses, in ankles with stepoffs between 1.0 and 4.0mm of the anterolateral articular surface, increased by between 2.3 x and 3.0 x compared to the corresponding intact ankle values. Peak instantaneous contact stress gradients in stepoff configurations increased by between 1.9 x and 2.6 x the corresponding intact configuration values. Anatomic reduction of the displaced fragment restored intact contact stresses and contact stress gradients. Intact and anatomic configurations demonstrated a heterogeneous population of low-magnitude, randomly oriented contact stress gradient vectors in contrast to high-magnitude, preferentially oriented gradients in stepoff configurations. Peak instantaneous contact stresses may be important pathomechanical determinants of post-traumatic arthritis. Abnormal contact stress gradients could cause regional pathological disturbances in cartilage stress and interstitial fluid distribution. Measuring contact stresses and contact stress gradients during motion allowed potential incongruity-associated pathologic changes in loading that occur over the complete motion cycle to be investigated.

Ankle Joint↗

Abnormal viscoelastic behaviour of passive ankle joint movement in diabetic patients: an early or a late complication?

AIMS/HYPOTHESIS: The goal of the present study was to compare the range of motion and both the viscous and elastic components of passive ankle joint movement in short- and long-term diabetic patients with that of a control population. METHODS: Thirty-four diabetic patients and 16 control subjects entered into the study. Patients with a history of over 15 years of diabetes were considered as a long-term diabetic group. In order to quantify the passive ankle joint movement, a device was designed to measure the dorsi- and plantar-flexion angle and the net moment at the ankle. Elastic behaviour was examined as the separate slope of regression lines (stiffness) of plantar and dorsal components in the loading moment-angle curve. It was also examined as the slope of the regression line in the final 10% of each component. Hysteresis, a characteristic of viscoelastic materials that indicates loss of energy during unloading, was corrected for range of motion and used to examine viscous behaviour of the ankle joint. RESULTS: Total and plantar ranges of motion were significantly lower in long-term diabetic patients than in short-term diabetic and control groups (p < 0.05). Plantar-flexion stiffness was significantly lower in short-term diabetic patients than in control subjects and long-term diabetic groups (p < 0.05). Corrected hysteresis was significantly higher in long-term diabetic than in short-term diabetic and control (p < 0.05) groups in the dorsal range of motion. CONCLUSIONS/INTERPRETATION: This study shows that both decreased plantar and total ankle joint ranges of motion, and increased viscous component of passive ankle joint movement are among the late complications of diabetes.

Ankle Joint↗