An algorithm for source checking continuous air monitors using radon progeny.

Abstract

Department of Energy requirements contained within 10CFR835 require that continuous air monitors be periodically checked for operability. The DOE air monitoring implementation guide for 10CFR835 allows the use of radon progeny to perform the recommended weekly source check. The Defense Waste Processing Facility located at the Savannah River Site has demonstrated that, through the use of the Hypotheses Concerning Two Means, diurnal change in the radon progeny detected by the monitors meets the requirements for weekly source checks. The use of the diurnal change in radon progeny has replaced the person-hours expended performing direct weekly source checking with an automated system requiring minimal person-hour expenditure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M G Hogue, A B Smith, D J Hadlock. 2000. An algorithm for source checking continuous air monitors using radon progeny.. https://doi.org/10.1097/00004032-200009000-00012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Radiation effects of the Chernobyl accident on the Hungarian population].

Due to the nuclear accident at Chernobyl in April 1986, the atmospheric transport spread the released radioactivity throughout the whole Europe. The initial plume moved into the north-western direction and a portion of this plum turned to west and later on to south-west. The central European countries including Hungary became affected in 29-30 April. The release during the last period (5-7 May) was directed to Romania, Bulgaria and Greece. In addition to the main trajectories of the atmospheric transport, the local meteorological conditions with winds of different directions at various altitudes, rainfalls etc. produced a very complex deposition pattern in Central Europe. The contamination of the soil surface and vegetation were strongly influenced by the wash-out of the radioactive materials from the local air. Due to the high geographical variation of the rains the surface contamination provided a similar heterogeneity among the territories of the country. The northern-west part and the region of the capital Budapest became nearly 5 times higher contaminated than the middle part of the country. Radiation doses of the population have been provided by activity concentrations in air, soil, vegetation, foods etc. and the external dose rates, mainly due to the surface contamination by the isotopes of 131I, 134Cs and 137Cs. The average effective dose contribution received by the individuals (adults) in Hungary during the 15 years following the accident has been assessed to be 0.30 mSv while the annual dose from the natural background is 2.5-3 mSv. Contribution to total dose from the internal pathway (committed effective dose) resulted about 0.10 mSv and the external radiation provided 0.19 mSv. The contributions of the external exposure from the contaminated air and inhalation are less than 5% of the total one.

Air Pollutants, Radioactive↗

Variations in the concentration of radon in parts of the Ogof Ffynnon Ddu system, Penwyllt, South Wales and estimates of doses to recreational cavers.

A new winter and summer investigation of radon concentrations in parts of the Ogof Ffynnon Ddu system at Penwyllt, South Wales, has been carried out using 100 environmental National Radiological Protection Board track etch detectors. Fifty detectors were installed in the system in December 1998 and again in August 1999 for a period of a month. The data obtained confirm that the system has moderately high radon concentrations with a system mean of 2318 Bq m(-3) in winter and 2844 Bq m(-3) in summer. Traverse means have a summer high of 3094 Bq m(-3) for OFDI to Cwm Dwr and a winter low of 1946 Bq m(-3). The extremely high concentrations approaching 20,000 Bq m(-3), reported previously from the system (Hyland, 1995), have not been reproduced. The data show that the airflow directions at the entrances are not what might have been predicted. Air appears to be largely continuously emerging from the lowest entrance but, at the higher entrances, conversely to the predictions, in winter air enters and in summer appears to be coming out or is variable. Internally, there are sites that in winter have very low radon concentrations that can only be explained by the ingress of fresh air. These are not matched in the summer experiment, again indicating that ingress of fresh air to some parts of the system is very variable. The data illustrate the complexity of airflow within a multi-entrance system but behind these variations several mean concentrations can be obtained from which an approximation of the dose likely to be received can be calculated. Using the maximum mean concentration obtained, 3094 Bq m(-3), and using the latest dose conversion, a 10 h underground trip in the Ogof Ffynnon Ddu system yields a calculated dose of 0.12 mSv. Given that the recommended limit for a member of the public is 1 mSv, this dose would be reached after about 80 h of caving in the system.

Air Pollutants, Radioactive↗