PubMed Health⌕ Search

PubMed · 10960855

A method for quantifying artefacts in mapping methods illustrated by application to headbanging.

Abstract

Maps of disease rates (and other quantities) often must contend with variance associated with variable population sizes and low incidence within spatial units. These characteristics can lead to substantial statistical noise that can mask underlying spatial variation. As Gelman and Price illustrated, most conventional mapping methods fail to address this problem, and in fact can introduce statistical artefacts; mapped quantities can show spatial patterns even when there are no spatial patterns in the underlying parameter of interest. Kafadar evaluated the performance of the headbanging algorithm for spatial smoothing (Tukey and Tukey, Hansen) for eliminating small scale variation and preserving edge structure. Here we perform a simulation study to investigate the artefacts of maps smoothed by unweighted and weighted headbanging. We find substantial artefacts that depend on the spatial structure of the statistical variation (for example, the spatial pattern of sample sizes) and on the details of the spatial distribution of geographic units. The methods used here could readily be adapted to study other spatial smoothers; we choose headbanging because (i) it is an important method used in practice, and (ii) its heavily computational nature is naturally studied using simulation (in contrast to the analytical methods used by Gelman and Price).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Gelman, P N Price, C Y Lin. A method for quantifying artefacts in mapping methods illustrated by application to headbanging.. https://doi.org/10.1002/1097-0258(20000915%2F30)19%3A17%2F18%3C2309%3A%3Aaid-sim571%3E3.0.co%3B2-h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗