High-speed digital microscopy.

Abstract

High-speed imaging is an ideal technique to accurately resolve the temporal and spatial characteristics of rapid events at either the molecular or cellular level. In this article, the digital imaging techniques used to simultaneously acquire transillumination phase-contrast images, at 240 images s(-1) (high-speed), to characterize ciliary beat frequency, and fluorescence images, at 30 images s(-1) (fast), to measure intracellular calcium concentration ([Ca2+]i), are described. With this technique, a precise correlation between the changes in ciliary beat frequency with changes in [Ca2+]i can be made. Simultaneous imaging is achieved by using different wavelengths of light to form the phase-contrast and fluorescent images and selectively directing these light wavelengths to different cameras with dichroic mirrors and bandpass filters. High-speed images compatible with standard video recording equipment are obtained by prematurely resetting the raster scan of a CCD camera with additional vertical synchronization pulses. The fast [Ca2+]i images are determined using the ratiometric dye fura-2 and a recording technique that monitors rapid changes in fluorescence at a single wavelength and uses intermittent reference images for calibration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Sanderson. 2000. High-speed digital microscopy.. https://doi.org/10.1006/meth.2000.1022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Projection access order in algebraic reconstruction technique for diffuse optical tomography.

Algebraic reconstruction technique (ART) is one of the popular image reconstruction techniques used in diffuse optical tomography (DOT). We investigate in this note the influence of the order in which data are accessed in ART. Simulations mimicking breast tissues in transmission geometry with contrast agent tumour enhancement were used to evaluate the image quality of the diverse projection access investigated. We show that by selecting proper projection access order, the convergence speed can be significantly improved when ART is used to perform DOT. Moreover, low-contrast detection is improved.

Image Processing, Computer-Assisted↗

Projected digital radiologic images for teaching: balance of image quality with data size constraints.

RATIONALE AND OBJECTIVES: The authors performed this study to determine, in the context of a teaching presentation with slides, the information content needed in a digitized radiologic image for it to be equivalent in quality to an analog image. MATERIALS AND METHODS: Eleven sets of radiologic images were obtained from a teaching file collection and digitized. The images were scanned at high resolution and saved as image files. The information content of each image was then halved repeatedly with repeat sampling of the image. This procedure was repeated nine times to yield a total of 10 images with an information content that ranged from very low (32 kB) to high (12 MB). Each of these image files was made into a 35-mm slide by using a digital slide maker. The original radiographs were subsequently made into slides by using conventional photographic methods. Care was taken to make the images identical in every respect except digitization and information content. The slides were shown to radiologists, who filled out questionnaires to rate image quality. RESULTS: Digitized slides that contain an average of 416 kB of data (the equivalent of a 750 x 570-pixel matrix with 8-bit gray levels) were equivalent to analog images for 90% of viewers. At 830 kB (1,060 x 800-pixel matrix with 8-bit gray levels), 100% of viewers found no difference between digitized and analog images. CONCLUSION: Digital images become indistinguishable from analog images if a sufficient amount of information is retained in the digital image. There is a defined relationship between the perception of quality and the information content of a digital image.

Image Processing, Computer-Assisted↗

Measurement of the three-dimensional microscope point spread function using a Shack-Hartmann wavefront sensor.

We present a technique to measure the wavefront in the exit pupil of a microscope to determine the microscope's three-dimensional point spread function (PSF) experimentally. The wavefront yields the microscope PSF through a Fourier transform that models propagation of light from the exit pupil to the image plane. A Shack-Hartmann wavefront sensor is used to measure the wavefront shape by recording lateral displacements of a grid of focused spots created by a lenslet array. The displacement of each spot is related to the local wavefront slope. Thus, with appropriate sampling across the exit pupil, the entire wavefront can be reconstructed. This technique does not require the use of a sub-resolution object to obtain the three-dimensional microscope PSF. Consequently, larger, brighter fluorescent objects may be imaged, thereby reducing the requirements for detector sensitivity and leading to a three-fold increase in the axial range over which the PSF is measured. The Shack-Hartmann technique results in a description of the PSF as a continuous function whose sampling is not dependent on the size of the CCD pixels. The Shack-Hartmann sensor is not limited by the numerical aperture of the objective and can easily be calibrated to measure the PSF at any wavelength.

Image Processing, Computer-Assisted↗