PubMed Health⌕ Search

PubMed · 1096834

Pneumothorax in the newborn. Changing pattern.

Abstract

The clinical course of pneumothorax and its allied conditions was studied in 34 newborn infants who presented over a 2 1/2-year period. We found an overall incidence of 3/1000 live births. 11 term infants without obvious pulmonary pathology presented early (9 within minutes of birth); 6 of these had aspirated meconium or blood. The remaining 23 were preterm infants with hyaline membrane disease (HMD) and accounted for 68% of the infants in this series. In contrast, they presented late (mean 45 hours) and 16 were on continuous distending pressure (CDP) or intermittent positive pressure ventilation (IPPV) at the onset of pneumothorax. 15% of all infants with HMD who required CDP/IPPV developed pneumothorax; this increased incidence was most evident in infants who received CDP only. All except 2 of the 11 term infants in the first group were managed conservatively and all survived. Wehn pneumothorax occurred as a complication of HMD in preterm infants, 14 of the 16 infants required intrapleural drainage. Persistence or recurrence of pneumothorax occurred in 9 infants, 7 of whom were receiving CDP/IPPV at the time. Lung expansion was affected only after replacement with a patent chest drain through the same incision or insertion of a second drain on the same side of the chest. All 5 deaths occurred in the group of preterm infants with HMD. 3 resulted directly form respiratory failure due to severe HMD complicated by pneumothorax. We emphasize the increasing importance of pneumothorax as a complication of HMD in preterm infants, particularly in those receiving CDP. Successful management depends on prompt diagnosis and treatment of pneumothorax, which may occur as unexplained sudden deterioration at any time during the course of illness in this group of high risk infants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Y Yu, S W Liew, N R Robertson. 1975. Pneumothorax in the newborn. Changing pattern.. https://doi.org/10.1136/adc.50.6.449

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗