PubMed Health⌕ Search

PubMed · 10999634

Miniaturized thin-layer radial flow cell with interdigitated ring-shaped microarray electrode used as amperometric detector for capillary electrophoresis.

Abstract

A chip-type thin-layer radial flow cell was developed as an amperometric detector for capillary electrophoresis. We fabricated a carbon film-based interdigitated ring-shaped array (IDRA) microelectrode with a 2 microm bandwidth and an almost 1 microm gap on a glass plate and used it as a working electrode. A fused-silica capillary was arranged above the IDRA electrode using a guide hole drilled through the acryl plate that formed the flow cell lid. A flow channel for use in connecting the outlet capillary was also fabricated in the acryl plate. We characterized the analytical performance of the IDRA electrode in the microchip flow cell in terms of linear concentration range, sensitivity and concentration detection limit. We achieved a collection efficiency and catechol redox cycle at the IDRA microelectrode of 65% and 1.71, respectively, and thus a high sensitivity and low detection limit of 392.9 pA/microM and 15 nM for dopamine hydrochloride. We examined the reproducibility of the detector and found that the run-to-run and detector-to-detector relative standard deviations were both less than 10%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Z Liu, O Niwa, R Kurita, T Horiuchi. 2000-09-01. Miniaturized thin-layer radial flow cell with interdigitated ring-shaped microarray electrode used as amperometric detector for capillary electrophoresis.. https://doi.org/10.1016/s0021-9673(00)00632-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The HPA axis in HIV-1 infection.

Several lines of evidence suggest that neuroendocrine abnormalities in general and HPA axis activity in particular occur in both HIV-1 infection and individuals engaging in chronic drug use. For instance, our studies showing attenuated norepinephrine as well as ACTH and cortisol responses to a cold pressor challenge in asymptomatic HIV-1 persons support such a concept. Furthermore, our data on investigations on mirror-star tracing and speech challenges also support the finding that neuroendocrine responses are compromised in HIV-1 infection. Although the mechanisms leading to adverse effects on HPA axis activity in HIV infection are not fully understood, several lines of evidence suggest that a number of mechanisms may be involved, including homologies in molecular structures of various mediators of neuroendocrine activity and HIV-related structures, HIV as a chronic stress model, and virus-induced toxic factors. This article reviews our recent findings in this area and also presents research hypotheses needed for testing and understanding the mechanisms involved in the development of neuroendocrine abnormalities in HIV-1-infected injection drug users.

Catecholamines↗

Determination of catecholamines and metanephrines in urine by capillary electrophoresis-electrospray ionization-time-of-flight mass spectrometry.

A method successfully coupling capillary electrophoretic separation to time-of-flight mass spectrometric (TOFMS) detection for the simultaneous analysis of catecholamines (dopamine, norepinephrine, and epinephrine) and their O-methoxylated metabolites (3-methoxytyramine, normetanephrine, and metanephrine) is described. The inner capillary wall was coated with polyvinyl alcohol in order to obtain baseline resolution of catecholamines and metanephrines and to ensure reproducibility without extensive restorative washing of the capillary. Using electrokinetic injection, detection limits of 0.3 microM for dopamine and norepinephrine, 0.2 microM for 3-methoxytyramine and normetanephrine, and 0.1 microM for epinephrine and metanephrine were achieved with standard solutions. The usefulness of this approach was demonstrated by applying the developed method to the analysis of a spot collection of human urine from a healthy volunteer. The catecholamines and metanephrines were removed from the urine samples and preconcentrated by simultaneous SPE on cation-exchange sorbents. The recoveries of all analytes, with the exception of epinephrine (75%), were over 80%. Catecholamines and metanephrines in the urine samples were quantitated using 3,4-dihydroxybenzylamine as an internal standard. Submicromolar concentrations, consistent with the catecholamine and metanephrine levels reported for normal human urine, were detected.

Catecholamines↗