PubMed · 11002439

Radiographic quality control devices.

Abstract

In this study, we evaluate eight radiographic quality control (QC) devices, which noninvasively measure the output from a variety of diagnostic x-ray production systems. When used as part of a quality assurance (QA) program, radiographic QC devices help ensure that x-ray equipment is working within acceptable limits. This in turn helps ensure that high-quality images are achieved with appropriate radiation doses and that resources are used efficiently (for example, by minimizing the number of repeat exposures required). Our testing focused on the physical performance, ease of use, and service and maintenance characteristics that affect the use of these devices for periodic, routine measurements of x-ray system parameters. We found that all the evaluated models satisfactorily measure all the parameters normally needed for a QA program. However, we did identify a number of differences among the models--particularly in the range of exposure levels that can be effectively measured and the ease of use. Three models perform well for a variety of applications and are very easy to use; we rate them Preferred. Three additional models have minor limitations but otherwise perform well; we rate them Acceptable. We recommend against purchasing two models because, although each performs acceptably for most applications, neither model can measure low levels of radiation. This Evaluation covers devices designed to measure the output of x-ray tubes noninvasively. These devices, called radiographic quality control (QC) devices, or QC meters, are typically used by medical physicists, x-ray engineers, biomedical engineers, and suitably trained radiographic technologists to make QC measurements. We focus on the use of these devices as part of an overall quality assurance (QA) program. We have not evaluated their use for other applications, such as acceptance testing. To be included in this study, a device must be able to measure the exposure- and kVp-related characteristics of most x-ray systems. At minimum, it must be able to make routine QC measurements of general radiographic, fluoroscopic, and most mammographic equipment. We prefer that it also be usable with dental x-ray systems, more advanced mammography systems (see the supplementary article on page 103), and computed tomography (CT) systems. The device may be a single unit, or it may be a kit consisting of multiple components that, when combined, can perform all the relevant measurements. The evaluated devices are designed to assess only x-ray production systems, not x-ray detection systems such as image intensifiers and film. Those types of systems are typically assessed using test phantoms and other tools that produce test images, which can be quantitatively measured and compared against standards.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

2000. Radiographic quality control devices.. https://pubmed.ncbi.nlm.nih.gov/11002439/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗