PubMed Health⌕ Search

PubMed · 11021216

[Bioabsorbable polymer].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Yamaoka, Y Kimura. 2000. [Bioabsorbable polymer].. https://pubmed.ncbi.nlm.nih.gov/11021216/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biodegradation of carbonate apatite/collagen composite membrane and its controlled release of carbonate apatite.

The aim of this study was to investigate the biodegradation of carbonate apatite (CO(3)Ap)/collagen composite membrane as a new guided tissue regeneration membrane in vivo and to estimate its controlled release of CO(3)Ap in vitro. To control the biodegradation of the guided tissue regeneration membrane and to promote hard tissue regeneration in the periodontal region, we added CO(3)Ap into the collagen membrane. To investigate the biodegradation of CO(3)Ap/collagen composite membranes, the prepared membranes (CO(3)Ap:0, 10 wt %) were cut into 5 x 5 x 0.1 mm and subcutaneously implanted into the backside of male rats under general anesthesia. The explanted membranes were investigated histologically. To estimate their controlled release of CO(3)Ap in vitro, the membranes (CO(3)Ap 0-10 wt %, 5 x 5 x 0.1 mm) were immersed into collagenase solution and compulsorily dissolved for 48 h. Histological results suggested that the membrane had a good biocompatibility and the biodegradable period was shortened with the presence of CO(3)Ap. In the solubility experiments of the membrane, eluted Ca concentrations gradually increased with total dependence on the dissolution of the collagen membrane. Our study demonstrated that the biodegradation time can be controlled by CO(3)Ap contents in the membrane and CO(3)Ap could be released from the membrane with the biodegradation period.

Absorbable Implants↗

Calvarial bone distraction with a contractile bioresorbable polymer.

The aim of the present study was to evaluate the possibility of mobilizing calvarial bone with a fully implantable and bioresorbable device. The animal model used was the New Zealand white rabbit (n = 12). An island bone flap attached to the dura mater was created in the parietal region and amalgam markers were placed in this bone flap and in the ipsilateral frontal bone. In one group of six rabbits (group 1), a specially processed contractile 70L/30D,L polylactic acid plate, 15 x 6 x 0.6 mm, was attached to the island flap by one extremity, and to the fixed ipsilateral frontal bone by the other. In group 2 (control), no plate was added. Bone marker movement was followed with serial radiography. In group 1, there was a progressive reduction in mean marker distance over the first 48 hours, and stability thereafter. In group 2 (control), mean marker distance remained stable until the second postoperative week, after which time there was a slight increase until the end of the experimental period. At 4 weeks, the mean marker separation differed significantly between group 1 (mean, -3.62 mm; SD, 0.79 mm) and group 2 (mean, 0.34 mm; SD, 0.14 mm; p <0.001). In conclusion, a totally implantable and bioresorbable device was successfully used to mobilize calvarial bone. Polymer contractility will likely constitute the basis of a new generation of bioresorbable distractors for use in craniofacial surgery.

Absorbable Implants↗

Effect of bioabsorbable osseous fixation materials on dura mater and brain tissue.

Bioabsorbable materials are frequently used in pediatric cranial surgery, but the effects of these materials on neural tissue are not known. The authors assessed the histologic alterations to dura mater and brain tissue associated with bioabsorbable plates. Fifteen Sprague-Dawley rats were given sham cranial surgery; an additional 30 underwent placement of 8 x 8-mm polylactic acid/poly-glycolic acid plates. The rats were assessed weekly for neurologic or behavioral changes suggesting neural damage. A portion of each group was killed at 3, 6, and 12 months for histologic analysis of cranium, dura mater, and brain tissue by standard hematoxylin and eosin stain. None of the animals showed any behavioral changes or neurologic deficits. The plates were gradually hydrolyzed over the study period, and all had disappeared by 12 months. The histologic examination showed fibrous encapsulation around the plates, accompanied by foreign body giant cell reaction and calcification. Focal gliosis, where evident, was mild and confined primarily to the superficial cortex of the brain beneath the plate. The infiltration of the dura mater and underlying brain parenchyma was negligible. In conclusion, the neurologic and histologic effect of bioabsorbable plates on neural tissue may be considered negligible in the early postoperative period.

Absorbable Implants↗