PubMed Health⌕ Search

PubMed · 11026461

Using an MRI distortion transfer function to characterize the ghosts in motion-corrupted images.

Abstract

Motion artefact suppression remains an active topic in MRI. In this paper, we suggest that certain nonrigid, or spatially variant, characteristics of motion of an object can be represented by extending the work of Mitsa et al. This empirical extension uses a ghost distortion transfer function (GTDF) applied to the k-space (frequency domain) data. We demonstrate the variety of ghost characteristics that can be generated from various two-dimensional (2-D) GTDF's. The distortion transfer function for periodic motion along the Z-axis can be determined from the nonoverlapped portions of the ghost and central image. It required a GDTF with the shape of a belt bandpass filter to produce an image corresponding to the ghosts of a volunteer's abdomen image corrupted by unknown respiratory motion artefacts. The preliminary results of a composite method of motion artefact suppression are presented. The artefact suppression was successful for ghost images described by a GDTF have a low-pass nature, but less successful with ghosts have a GDTF of a bandpass nature.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Yang, M R Smith. 2000. Using an MRI distortion transfer function to characterize the ghosts in motion-corrupted images.. https://doi.org/10.1109/42.870663

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗