An adaptive 3-D discrete cosine transform coder for medical image compression.

Abstract

In this communication, a new three-dimensional (3-D) discrete cosine transform (DCT) coder for medical images is presented. In the proposed method, a segmentation technique based on the local energy magnitude is used to segment subblocks of the image into different energy levels. Then, those subblocks with the same energy level are gathered to form a 3-D cuboid. Finally, 3-D DCT is employed to compress the 3-D cuboid individually. Simulation results show that the reconstructed images achieve a bit rate lower than 0.25 bit per pixel even when the compression ratios are higher than 35. As compared with the results by JPEG and other strategies, it is found that the proposed method achieves better qualities of decoded images than by JPEG and the other strategies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Tai, Y G Wu, C W Lin. 2000. An adaptive 3-D discrete cosine transform coder for medical image compression.. https://doi.org/10.1109/4233.870036

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗