The combinatorial chemistry industry has made major advances in the handling and mixing of small volumes, and in the development of robust liquid-handling systems. In addition, developments have been made in the area of material handling for the high-throughput drug screening and combinatorial chemistry fields. Lastly, improvements in beamline optics at synchrotron sources have enabled the use of flash-frozen micron-sized (10-50 microm) crystals. The combination of these and other recent advances will make high-throughput protein crystallography possible. Further advances in high-throughput methods of protein crystallography will require application of the above developments and the accumulation of success/failure data in a more systematic manner. Major changes in crystallography technology will emerge based on the data collected by first-generation high-throughput systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R C Stevens. 2000. High-throughput protein crystallization.. https://doi.org/10.1016/s0959-440x(00)00131-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Automated large-volume sample stacking procedure to detect labeled peptides at picomolar concentration using capillary electrophoresis and laser-induced fluorescence detection.

We have developed an automated large-volume sample stacking (LVSS) procedure to detect fluorescein isothiocyanate-labeled peptides in the picomolar range. The injection duration is 10 min at 50 mbar to fill 62% of the capillary volume to the detection cell. The calculated limit of detection (S/N=3), filling 1% of the capillary volume, is 74 pM for bradykinin and 45 pM for L-enkephalin with samples diluted in water and analyzed in a 50 mM borate buffer, pH 9.2. With the automated LVSS system, the limits of detection are 7 pM for bradykinin, 3 pM for L-enkephalin and 2 pM for substance P. LVSS is shown to be quantitative from 500 to 10 pM.

Automation↗

Look, no hands.

Explore the source record for details and available documents.

Automation↗

Validation of a sensitive and automated 96-well solid-phase extraction liquid chromatography-tandem mass spectrometry method for the determination of desloratadine and 3-hydroxydesloratadine in human plasma.

To support clinical development, a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed and validated for the determination of desloratadine (descarboethoxyloratadine) and 3-OH desloratadine (3-hydroxydescarboethoxyloratadine) concentrations in human plasma. The method consisted of automated 96-well solid-phase extraction for sample preparation and liquid chromatography/turbo ionspray tandem mass spectrometry for analysis. [2H(4)]Desloratadine and [2H(4)]3-OH desloratadine were used as internal standards (I.S.). A quadratic regression (weighted 1/concentration(2)) gave the best fit for calibration curves over the concentration range of 25-10000 pg/ml for both desloratadine and 3-OH desloratadine. There was no interference from endogenous components in the blank plasma tested. The accuracy (%bias) at the lower limit of quantitation (LLOQ) was -12.8 and +3.4% for desloratadine and 3-OH desloratadine, respectively. The precision (%CV) for samples at the LLOQ was 15.1 and 10.9% for desloratadine and 3-OH desloratadine, respectively. For quality control samples at 75, 1000 and 7500 pg/ml, the between run %CV was </=7.5% for desloratadine and </=6.3% for 3-OH desloratadine. Between run %bias ranged from 4.1 to 8.0% for desloratadine and -11.5 to -4.8% for 3-OH desloratadine. Desloratadine and 3-OH desloratadine were stable in human plasma for 401 days at -22 degrees C, after five freeze/thaw cycles, up to 24 h at room temperature, and in reconstituted sample extracts (up to 185 h at 5 degrees C). This LC-MS-MS method for the determination of desloratadine and 3-OH desloratadine in human plasma met regulatory requirements for selectivity, sensitivity, goodness of fit, precision, accuracy and stability.

Automation↗