Cerenkov counting.

Abstract

When auditing research laboratories, health physics personnel are often alarmed to find liquid scintillation vials that only contain filters and no cocktail. They are then surprised when lab personnel state that they don't need cocktail to count their samples. While not frequently used by the health physicist, counting of samples by using Cerenkov radiation is valid and advantageous when correctly used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A BenZikri. 2000. Cerenkov counting.. https://doi.org/10.1097/00004032-200011001-00008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood.

The development of a hypoglycemic alarm system using a subcutaneous glucose sensor implies that a decrease in blood glucose is rapidly followed by a decrease in the signal generated by the sensor. In a first set of experiments the linearity and the kinetics of the response of sensors implanted in the subcutaneous tissue of normal rats were investigated during a progressive increase in plasma glucose concentration: the sensitivities determined between 5 and 10 mM and between 10 and 15 mM were not significantly different, and a 5-10 min delay in the sensor's response was observed. In a second set of experiments, performed in diabetic rats, the kinetics of the decrease in subcutaneous glucose concentration following insulin administration was monitored during a decrease in plasma glucose level, from 15 to 3 mmol/L. During the 20 first min following insulin administration, the sensor monitored glucose concentration in subcutaneous tissue with no lag time. Subsequently, the decrease in the estimation of subcutaneous glucose concentration preceded that of plasma glucose. This phenomenon was not observed when the same sensors were investigated in vitro during a similar decrease in glucose concentration and may be due to a mechanism occurring in vivo, such as the effect of insulin on glucose transfer from the interstitial space to the cells surrounding the sensor. It reinforces the interest of the use of implantable glucose sensors as a part of a hypoglycemic alarm.

Scintillation Counting↗

The high count rate performance of a two-dimensionally position-sensitive detector for positron emission tomography.

In positron tomographs using a small number of position-sensitive detectors, each detector must operate at high singles event rates, especially during dynamic studies. To enable the PENN-PET tomography to perform studies involving high data rates, the high count rate behaviour of the position-sensitive scintillation detector used in the tomograph was investigated at singles rates in excess of 2 million counts per second (MCPS). Detector dead-time, minimised through the use of pulse clipping (clipping time, 120 ns), is a maximum of 20% at the highest data rates. At 2 MCPS and 240 ns pulse integration time, the full width at half maximum of the point spread function (PSF) worsens by approximately 20% over its low count rate value of 5.2 mm. Furthermore, at high count rates, pulse pile-up produces long tails in the PSF along the detector's long axis. These tails were reduced or eliminated through the use of a shortened pulse integration time (160 ns instead of 240 ns), an upper level energy discriminator and a local centroid event positioning algorithm. Detector performance was characterised for different combinations of these event processing techniques, and the mechanisms by which pulse pile-up distorts the high count rate PSF were investigated using computer simulations. With the incorporation of the high count rate event processing techniques, the detector's count rate capability enables the PENN-PET tomograph to handle most current imaging protocols.

Scintillation Counting↗