RSD requirement for different sample size for blend sampling.
Abstract
A formula for calculating the equivalent relative standard deviation (RSD) for different sample sizes other than the Office of Generic Drugs (OGD) draft guidance was derived. These critical values vary with the population RSD and the sample size and guarantee the same confidence of passing a batch similar to the OGD blend uniformity test. Simulation results showed that the normal approximations give very close results to the simulation results. An assessment of the proposed OGD blend uniformity criteria against the first-stage USP content uniformity (CU) criteria for tablets was also made.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
H Saranadasa. 2000. RSD requirement for different sample size for blend sampling.. https://doi.org/10.1081/ddc-100100994