PubMed Health⌕ Search

PubMed · 11080693

Application of QuantiGene nucleic acid quantification technology for high throughput screening.

Abstract

To identify inhibitors of interleukin-8 (IL-8) production, a high throughput assay was developed using the QuantiGene nucleic acid quantification kit that employs branched-chain DNA (bDNA) technology to measure the mRNA directly from cells. Unlike polymerase chain reaction and other technologies that employ target amplification, the QuantiGene system uses signal amplification. To perform the assay, various molecular probes capable of hybridizing with IL-8 mRNA were designed and synthesized. A human lung epithelial cell line was treated with interleukin-1alpha (IL-1alpha) to stimulate the IL-8 gene expression and the mRNA was measured using the QuantiGene system. The QuantiGene assay was sensitive, flexible, and reproducible and achieved equivalent or better sensitivity than promoter-reporter assays, and eliminated the time required for constructing a promoter-reporter system. Our data show that bDNA technology has the potential to be used as a high throughput screening assay.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Warrior, Y Fan, C A David, J A Wilkins, E M McKeegan, J L Kofron, D J Burns. 2000. Application of QuantiGene nucleic acid quantification technology for high throughput screening.. https://doi.org/10.1177/108705710000500506

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Real-time PCR quantification of genital shedding of herpes simplex virus (HSV) and human immunodeficiency virus (HIV) in women coinfected with HSV and HIV.

The accuracy and usefulness of laboratory-developed real-time PCR procedures using a Light Cycler instrument (Roche Diagnostics) for detecting and quantifying human immunodeficiency virus type 1 (HIV-1) RNA and DNA as well as herpes simplex virus type 1 (HSV-1)/HSV-2 DNA in cervicovaginal secretions from women coinfected with HIV and HSV were evaluated. For HIV-1, the use of the NEC152 and NEC131 primer set and the NEC-LTR probe in the long terminal repeat gene allowed us to detect accurately the majority of HIV-1 subtypes of group M circulating in sub-Saharan Africa, including subtypes A, B, C, D, and G as well as circulating recombinant forms 02 and 11. The detection threshold of real-time PCR for HIV in cervicovaginal lavage samples was 5 copies per assay for both RNA and DNA; the intra- and interassay coefficients of variation of C(T) values were 1.30% and 0.69% (HIV-1 RNA) and 1.84% and 0.67% (HIV-1 DNA), respectively. Real-time PCR for HSV using primers and probe targeting the HSV DNA polymerase gene allowed both detection and quantification of HSV DNA and also differentiation between HSV-1 and HSV-2 genotypes. The detection threshold of real-time PCR for HSV was 5 copies per assay; the intra- and interassay coefficients of variation of C(T) values were 0.96% and 1.49%, respectively. Both manual and automated silica-based procedures were appropriate for combined extraction of HIV and HSV genomes from female genital secretions. Taken together, these findings indicate that real-time PCR may be used as a unique nucleic acid amplification procedure to detect and quantify HIV and HSV genomes in cervicovaginal secretions and thus to assess at reduced costs the genital shedding of both viruses in women included in intervention studies.

Branched DNA Signal Amplification Assay↗

Clinical performance of the new rRoche COBAS TaqMan HCV Test and High Pure System for extraction, detection and quantitation of HCV RNA in plasma and serum.

We evaluated the Roche COBAS TaqMan HCV Test For Use With The High Pure System (TaqMan HPS; Roche Diagnostics), for the extraction, detection and quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The TaqMan HPS is a real-time PCR assay with a reported linear dynamic range of 3.0x10(1) to 2.0x10(8) HCV RNA IU/ml, and a reported lower limit of detection (LLD) of 10 IU/ml. Calculation of the HCV RNA titre is based upon an external standard curve in the presence of an internal control. Intra-assay and inter-assay variation were small in reference panel members with HCV RNA > or =100 IU/ml. Genotype performance and quantitative correlation between the TaqMan HPS and the bDNA (VERSANT HCV 3.0 assay; Bayer Diagnostics), assessed in 59 patient samples, were good for HCV genotype 1 but poor for genotypes 2, 3 and 4. For genotypes 2, 3 and 4, values obtained from the TaqMan HPS were in general 0.5 log lower than those from the bDNA. Sensitivity was poor in low viral titre samples of genotypes 1, 2, 3 and 4. The LLD (95%) was estimated at 41 HCV RNA IU/ml for genotype 4. The TaqMan HPS underestimates HCV RNA at all levels in plasma and serum from HCV-infected individuals, and the LLD should be reconsidered. This is clinically relevant because underestimation of HCV RNA levels during therapy may lead physicians into making incorrect treatment decisions.

Branched DNA Signal Amplification Assay↗

A comparative evaluation between real time Roche COBas TAQMAN 48 HCV and bDNA Bayer Versant HCV 3.0.

The HCV virus is a common human pathogen made of a single stranded RNA genome with 9600nt. This work compared two different commercial methods used for HCV viral load, the bDNA Bayer Versant HCV 3.0 and the RealTime Roche COBAS TaqMan 48 HCV. We compared the reproducibility and linearity of the two methods. Seventy-five plasma samples with genotypes 1 to 4, which represent the population (45% genotype 1; 24% genotype 2; 13% genotype 3; 18% genotype 4) were directly processed with the Versanto method based upon signal amplification; the same samples were first extracted (COBAS Ampliprep - TNAI) and then amplified using RealTime PCR (COBAS TaqMan 48). The results obtained indicate the same performance for both methods if they have genotype 1, but in samples with genotypes 2, 3 and 4 the RealTime PCR Roche method gave an underestimation in respect to the Bayer bDNA assay.

Branched DNA Signal Amplification Assay↗