A microfabricated fluidic device that combines micellar electrokinetic chromatography and high-speed open-channel electrophoresis on a single structure for the rapid automated two-dimensional analysis of peptides has been devised and demonstrated. The microchip operates by rapidly sampling and analyzing effluent in the second dimension from the first dimension. Second-dimension analyses are performed and completed every few seconds, with total analysis times of less than 10 min for tryptic peptides. The peak capacity of the two-dimensional separations has been estimated to be in the 500-1000 range. The orthogonality of the separation techniques, an important factor for maximizing peak capacity or resolution elements, was verified by examining each technique independently for peptide separations. The two-dimensional separation strategy was found to greatly increase the resolving power over that obtained for either dimension alone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R D Rocklin, R S Ramsey, J M Ramsey. 2000-11-01. A microfabricated fluidic device for performing two-dimensional liquid-phase separations.. https://doi.org/10.1021/ac000578r

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quality assurance of biological monitoring in occupational and environmental medicine.

Biological monitoring of chemical exposure in the workplace has become increasingly important in the assessment of health risk as an integral part of the overall occupational health and safety strategy. In environmental medicine biological monitoring plays also an important role in the assessment of excessive, acute or chronic exposure to chemical agents. To guarantee that the results obtained in biological monitoring are comparable with threshold limit values and results from other laboratories, the analysis must be carried out with tested and reliable analytical methods and accompanied by a quality assurance scheme. Confounding influences and interferences during the pre-analytical phase can be minimised by recommendations from experienced laboratories. For internal quality control commercially available control samples with an assigned concentration are used. External quality control programs for biological monitoring are offered by several institutions. The external quality control program of the German Society of Occupational and Environmental Medicine has been organised since 1982. In the meantime the 27th program has been carried out offering 96 analytes in urine, blood and plasma for 47 substances. This program covers most of the parameters relevant to occupational and environmental medicine. About 350 laboratories take part in these intercomparison programs. At present, ten German and 14 international laboratories are commissioned to determine the assigned values. The data evaluated from the results of the intercomparison programs give a good overview of the current quality of the determination of analytes assessed in occupational and environmental toxicological laboratories. For the analysis of inorganic substances in blood and urine the tolerable variation ranges from 7.5 to 43.5%. For organic substances in urine the tolerable variation ranges from 12 to 48%. The highest variations (36-60%) were found for the analysis of organochlorine compounds in plasma. The tolerable variations for the determination of solvents in blood by head space gas chromatography range from 26 to 57%. If the recommendations for the pre-analytical phase, the selection of reliable analytical methods by the laboratory and the carrying out of adequate quality control are observed, the pre-requisites for reliable findings during biological monitoring are fulfilled

Chromatography↗