PubMed Health⌕ Search

PubMed · 11104914

Three-dimensional knee analyzer validation by simple fluoroscopic study.

Abstract

Introduction: The complexity of the knee articulation makes its clinical evaluation extremely difficult. Insufficiency of existing instruments for knee evaluation prevents physicians from providing a diagnosis of injury and/or an evaluation of different treatments. To this end, our research group has developed a functional knee analyzer, which allows a three-dimensional evaluation of the knee in motion. The goal of this study is to scientifically validate the functional knee analyzer before using it in clinical setting. Materials and methods: The three-dimensional knee analyzer includes an orthoplastic exoskeleton attachment system, a kinematic tracking device, a screen for graphical display and a C(++) program with a user interface for calculating kinematic indices. A fluoroscopic study was performed on five healthy subjects with a mean age of 28. The experiment was set-up to determine the reduction of skin movement with respect to the underlying bone by using a knee exoskeleton attachment system. The root mean square (RMS) errors of markers movement about the abduction-X (RMSRx) and tibial rotation-Z (RMSRz) axes and displacement in the XZ plane (RMSpxpz) were calculated, once by placing markers directly on the skin and once on the exoskeleton attachment system. Results: Our results demonstrated that RMSpxpz, RMSRx and RMSRz were reduced by a factor of 6 (min 1.8, max 26), 4.3 (min 0.75, max 21) and 6.2 (min 2, max 26.4) on average, respectively, for four subjects out of five when the exoskeleton attachment was used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Ganjikia, N Duval, L Yahia, de Guise J. 2000-12-01. Three-dimensional knee analyzer validation by simple fluoroscopic study.. https://doi.org/10.1016/s0968-0160(00)00063-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effectiveness of high-dose versus standard-dose influenza vaccines against hospitalisation according to frailty risk: a prespecified analysis of the randomised trial DANFLU-2.

BACKGROUND: Frailty is a major risk factor for influenza-related complications and can influence vaccine effectiveness. We aimed to assess the relative vaccine effectiveness (rVE) of high-dose (HD-IIV) versus standard-dose inactivated influenza vaccine (SD-IIV) in older adults aged 65 years or older according to frailty risk. METHODS: This study was a prespecified analysis of DANFLU-2, an open-label, individually randomised trial, conducted in Denmark during three consecutive influenza seasons (2022-23, 2023-24, and 2024-25). Adults aged 65 years or older were randomised (1:1) to the HD-IIV or SD-IIV group. The primary endpoint was hospitalisation for influenza or pneumonia. Frailty was defined according to the validated Hospital Frailty Risk Score (HFRS) based on ICD-10 codes within 10 years before randomisation. Participants were stratified into three HFRS categories, namely low (<5 points), intermediate (5-15 points), and high (>15 points) frailty risk. The rVE of HD-IIV versus SD-IIV against the primary endpoint was assessed across prespecified HFRS categories and treating HFRS as a continuous variable. Pearson's chi-square test was used to compare safety events across frailty risk groups and randomisation groups. FINDINGS: Among 332&#x2009;438 randomised participants (mean age 73&#xb7;7 years [SD 5&#xb7;8]; 161&#x2009;538 [48&#xb7;6%] were female), 276&#x2009;173 (83&#xb7;1%) had low frailty risk, 52&#x2009;395 (15&#xb7;8%) had intermediate frailty risk, and 3861 (1&#xb7;2%) had high frailty risk. The primary endpoint of hospitalisation for influenza or pneumonia occurred in 1424 (0&#xb7;5%) of 276&#x2009;173 participants with low frailty risk, 761 (1&#xb7;5%) of 52&#x2009;395 with intermediate frailty risk, and 163 (4&#xb7;2%) of 3861 with high frailty risk (relative risk [RR] for intermediate vs low frailty risk 2&#xb7;8 [95% CI 2&#xb7;6-3&#xb7;1]; RR for high vs low frailty risk 8&#xb7;2 [7&#xb7;0-9&#xb7;6]). HFRS as a continuous variable significantly modified the effect of HD-IIV versus SD-IIV against the primary endpoint with higher rVE estimates with increasing HFRS (pinteraction=0&#xb7;020). The rVE was 0&#xb7;2% (95% CI -10&#xb7;8 to 10&#xb7;2) among those with low frailty risk, 13&#xb7;1% (-0&#xb7;4 to 24&#xb7;8) among those with intermediate frailty risk, and 19&#xb7;9% (-10&#xb7;3 to 42&#xb7;1) among those with high frailty risk. No significant interaction was observed when HFRS was assessed according to the prespecified categorical frailty groups (pinteraction=0&#xb7;17). The proportion of participants with at least one serious adverse event increased across frailty risk groups (13&#x2009;366 [4&#xb7;8%] of 275&#x2009;795 for low frailty risk, 5475 [10&#xb7;5%] of 52&#x2009;315 for intermediate frailty risk, and 777 [20&#xb7;2%] of 3850 for high frailty risk; p<0&#xb7;0001), with similar proportions of serious adverse events in the HD-IIV and SD-IIV groups for each frailty risk group. INTERPRETATION: Among adults aged 65 years or older in Denmark, frailty risk might modify the effects of HD-IIV versus SD-IIV against hospitalisation for influenza or pneumonia, with higher rVE estimates with increasing frailty risk. These findings might support considering high-dose influenza vaccines for frail older adults. However, effect modification was not evident when frailty was assessed using prespecified categorical subgroups, and subgroup-specific estimates were imprecise, with 95% CIs crossing the null. These results should be considered exploratory, warranting further investigation. FUNDING: The DANFLU-2 trial was funded by Sanofi.

Journal Article↗