Abstract

UNLABELLED: The non-ideal properties of solutions containing high concentrations of macromolecules can result in enormous increases in the activity of the individual macromolecules. There is considerable evidence that macromolecular crowding and confinement not only occur in cells, but that these are major determinants of the activity of the proteins and other intracellular macromolecules. This concept has important implications for cell volume regulation because, under crowded conditions, relatively small changes in concentration, consequent to alterations of water content, lead to large changes in macromolecular activity which could provide a mechanism by which cells sense changes in their volume. This brief review considers 1) direct demonstrations that introducing a high concentration of appropriate macromolecules into cells in vitro produced volume regulatory changes, 2) the physical chemical principles involved in the effects of crowding of macromolecules on their activity, 3) estimates of the actual intracellular activity of macromolecules, 4) a proposed model of how changes in macromolecular crowding could signal volume regulation in cells, and 5) brief consideration of the complexities introduced by interactions between macromolecules, water and cosolutes. CONCLUSIONS: The hypothesis that macromolecular crowding provides a mechanism by which cells sense changes in their volume is plausible and is supported by striking observations in red blood cell ghosts and perfused barnacle muscle cells. However, the signaling molecules involved have not been identified, the proposed model is not fully consistent with the experiments, experimental verification in intact cells is lacking, and numerous alternative or additional mechanisms are not excluded.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M B Burg. 2000. Macromolecular crowding as a cell volume sensor.. https://doi.org/10.1159/000016371

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

pH and cell volume effects on H2O and phosphoryl resonance splitting in rapid-spinning NMR of red cells.

Two resonances are seen in the (1)H-NMR spectrum of water in erythrocyte suspensions spun at the magic angle, a broad signal from water inside the cells and a sharp signal from extracellular water. The splitting is a result of a true chemical shift difference between the two populations, as bulk magnetic susceptibility effects are negated at the magic angle. The pH dependence of this chemical shift difference in erythrocyte suspensions was investigated. Splittings of 16.7 +/- 0.1, 18.9 +/- 0.9, and 21.0 +/- 0.2 Hz were observed at pH 6.0, 7.0, and 8.5, respectively; however, this was accompanied by a change in the mean cell volume. To account for any contribution from the volume change, the osmolality of the pH 6.0 and 8.5 suspensions was adjusted to equalize the cell volume between samples at the three pHs. Under these conditions, the splitting was 18.3 +/- 0.1 and 18.6 +/- 0.1 Hz at pH 6.0 and 8.5, respectively. Thus the observed chemical shift difference between the two water resonances was independent of pH. Therefore the splitting of the water resonance was concluded to be directly proportional to the protein concentration within the cell. Measurements of the magnetic susceptibility difference between the two compartments were also carried out, yielding a value of 2.0 +/- 0.2 x 10(-7) (SI units) for erythrocytes in isotonic saline at pH 7.0.

Cell Size↗

Correlation between erythrocytes deformability and size: a study using a microchannel based cell analyzer.

The deformability of erythrocytes is of great importance for oxygen delivery in the microcirculation [Lipowsky, H.H., 2005. Microvascular rheology and hemodynamics. Microcirculation 12, 5-15]. Aging of erythrocytes is associated with a reduction in deformability and also in size. The present work describes an automated cell analyzer which utilizes a glass microchannel and advanced image processing software. Erythrocytes suspended in a high viscosity medium are filmed flowing through the microchannel. Under these conditions, the cells assume different orientations and undergo varying deformations according to their location in the velocity profile. The cell analyzer enables the measurement of individual erythrocyte velocity, deformability and volume at varying depths within the microchannel. The volume of the cells is calculated based on the experimental data and a fluid mechanics model. The results obtained show that, on average, the deformability of the cells increases with increase in their size. Additionally, the behavior of RBCs in a microchannel is investigated, showing promising diagnostic possibilities.

Cell Size↗

Microtubule organization in three-dimensional confined geometries: evaluating the role of elasticity through a combined in vitro and modeling approach.

Microtubules or microtubule bundles in cells often grow longer than the size of the cell, which causes their shape and organization to adapt to constraints imposed by the cell geometry. We test the reciprocal role of elasticity and confinement in the organization of growing microtubules in a confining box-like geometry, in the absence of other (active) microtubule organizing processes. This is inspired, for example, by the cortical microtubule array of elongating plant cells, where microtubules are typically organized in an aligned array transverse to the cell elongation axis. The method we adopt is a combination of analytical calculations, in which the polymers are modeled as inextensible filaments with bending elasticity confined to a two-dimensional surface that defines the limits of a three-dimensional space, and in vitro experiments, in which microtubules are polymerized from nucleation seeds in microfabricated chambers. We show that these features are sufficient to organize the polymers in aligned, coiling configurations as for example observed in plant cells. Though elasticity can account for the regularity of these arrays, it cannot account for a transverse orientation of microtubules to the cell's long axis. We therefore conclude that an additional active, force-generating process is necessary to create a coiling configuration perpendicular to the long axis of the cell.