Abstract

The purpose of this study was to introduce a new robotic system for microsurgical procedures of the eye, ear, brain, face, and hand. The design and main features of the Robot Assisted MicroSurgery (RAMS) work station are described. In addition, compatibility with the operating-room table is assessed. The engineering components of the RAMS work station consist of a laptop computer, a joystick, a mouse, slave robot, VME and amplifier chassis, and safety control box. The mechanical part of the RAMS, the slave robot, is designed to simulate movements of the human upper extremity, which has five joints and six degrees of motion. The robot has a zero backlash in five joints, and can sustain full extension of loads over three pounds. The arm measures 2.5 cm in diameter, and it is 34.6 cm long from its base to its tip. The arm and its base weigh 2.5 kg. Motors and encoders on the robot are easily removable, allowing for the arm to be sterilized in an autoclave. Assessment of robotic positioning, time for setup, relative precision, and possible problems in the operating field are compared with human-assisted microsurgical procedures. Robotic arm positioning on the operating-room table differs for each type of procedure. For those involving the hand and upper extremity, the robotic arm base occupies 35 percent of the operating table; this is only 10 to 15 percent for human-assisted procedures. The setup time for robot-assisted procedures is longer than for human-assisted surgery. However, microsurgical manipulations with the RAMS are more rapid than the surgeon's motions. Therefore, depending on the type of procedure, the total operating time is comparable to human-assisted procedures. The movement of the RAMS was found to be more precise, in attempting to perform vascular and neural anastomoses. The authors conclude that concurrent use of the remote-controlled RAMS as a microsurgical assistant is applicable in microsurgery, with the advantages of greater precision and more rapid microsurgical manipulation. However, the long-term cost effectiveness of using this system as an assistant in microsurgery warrants further investigation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Siemionow, K Ozer, W Siemionow, G Lister. 2000. Robotic assistance in microsurgery.. https://doi.org/10.1055/s-2000-9383

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Revival of the side-to-side approach for distal coronary anastomosis.

Side-to-side anastomosis was employed by just ten proportional stitches while performing distal anastomosis during coronary artery surgery. This technique is simple and quick. Here this simple technique is described in detail and the postoperative status of grafted conduits is reported.

Anastomosis, Surgical↗

Review article: Indeterminate colitis--definition, diagnosis and management.

BACKGROUND: The term indeterminate colitis is imprecise and without a generally accepted definition. Nevertheless, it is a term that is commonly used by gastroenterologists, pathologists and surgeons. AIM: To offer an opinion supported by published data, about the appropriate use of the term indeterminate colitis by addressing a series of questions. METHODS: A PubMed database search was performed using the keywords, 'colitis' and 'inflammatory bowel disease' each combined individually with the following adjectives: 'indeterminate', 'unclassified', 'undefined', 'undiagnosed' and 'non-specific'. RESULTS: There is no generally accepted definition of indeterminate colitis. All current applications of the term rely on exclusionary criteria and there is no confirmatory diagnostic test. Nevertheless, the diagnosis of indeterminate colitis appears to be durable in a subgroup of patients, suggesting that this group represents a unique phenotype. CONCLUSIONS: Indeterminate colitis has expanded from a strictly defined, postcolectomy pathological diagnosis to become, in addition, a clinical diagnosis without generally accepted criteria. A diagnosis of indeterminate colitis should be qualified with descriptors for the diagnostic criteria applied.

Anastomosis, Surgical↗

Acellular dermal matrix grafts for prevention of microarterial thrombophlebitis.

OBJECTIVE: To examine the role of acellular dermal matrix grafts for prevention of microarterial anastomotic thrombophlebitis. DESIGN: Bilateral femoral artery microvascular anastomoses were created in the field of established wounds infected with Staphylococcus aureus in 12 rats. In each animal, 1 femoral microarterial anastomosis was wrapped with an acellular dermal matrix graft, and the contralateral femoral anastomosis was left unprotected. The incidence of femoral artery thrombosis was determined after 4 days by wound reexploration. SETTING: David Geffen School of Medicine, University of California, Los Angeles. MAIN OUTCOME MEASURE: The patency of femoral artery anastomoses was determined after 4 days by wound reexploration. RESULTS: The incidence of femoral artery thrombosis in vessels wrapped with acellular dermal matrix grafts was 17%. The incidence of femoral artery thrombosis in unprotected vessels was 100%. This difference was statistically significant (P<.05). CONCLUSION: Acellular dermal matrix grafts seem to have a protective effect in the prevention of acute thrombophlebitis when arterial microvascular anastomoses are performed in infected surgical fields.

Anastomosis, Surgical↗