PubMed Health⌕ Search

PubMed · 11131203

Diagnostic reference levels in interventional radiology.

Abstract

Following the release of European Directive EU 97/43, radiodiagnostic facilities within the European Union are required to implement a system of patient dose reviews based on comparisons with European, national and local diagnostic reference levels (DRLs). Establishing these levels for typical interventional radiology examinations presents a problem as definition of 'typical' examinations can be difficult, patient numbers are limited and these procedures are often performed at a few specialist centres. This paper uses dose-area product (DAP) gathered over a period of 3 years from 40 fluoroscopy rooms to investigate potential difficulties when it comes to forming diagnostic reference levels for interventional radiology. Comparison of DAP distributions with standard complex (fluoroscopy based) examinations such as barium enema reveals considerably more variation for interventional procedures. Two methods of forming a DRL are compared: pooled patient DAP distributions versus a distribution of DAP per room. The bootstrap resampling method is then applied to DAP distributions to form a confidence interval for the chosen DRL statistic. Potential error on a DRL formed at a local level from a limited number of patient dose readings and x-ray rooms is significant. The results are reviewed in the wider context of DRLs in general radiology. For complex examinations, it is suggested that the function of the DRL is best served by setting DRLs based on pooled size-corrected patient DAP distributions rather than distributions of average DAP per room.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N W Marshall, C L Chapple, C J Kotre. 2000. Diagnostic reference levels in interventional radiology.. https://doi.org/10.1088/0031-9155%2F45%2F12%2F323

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗