Detecting failed WBC-reduction processes: computer simulations of intermittent and continuous process failure.

Abstract

BACKGROUND: By regulation, ongoing process control of WBC-reduced processes is performed on 1 percent of WBC-reduced components, typically four to five samples per month. However, prospective study of the power of this small sample has been difficult. Using computer-generated "residual WBC" distributions, sample size sensitivity to continuous or intermittent WBC-reduction failure was examined. STUDY DESIGN AND METHODS: Populations of log-normally distributed values (mean +/- SD, 4.5+/-0.5; n = 10(5)) were generated. Continuous failure (log-normality maintained) was simulated by incrementally increasing the population mean or its SD. Intermittent failure (bimodal distributions with discrete subpopulations of WBCs > the FDA cutoff) was simulated by admixing increasing percentages of secondary outlier populations. Sample sizes of 4 to 60 were examined (500 repetitions each) for their power to detect drift or failure by standard control criteria. RESULTS: Normally distributed low variance failure was easily detected by comparison of the mean of four samples to an upper control limit (95% confidence of detecting 2% failure). However, 40 samples were required to detect > 5 percent intermittent (bimodal) failure or high variance failure with 90-percent confidence, and only if individual WBC values were compared to cutoff. CONCLUSION: Sampling error limits the detection of high variance or bimodal distributions. While the mean of a small sample is highly sensitive to shifts in a low-variance normal distribution, the detection of a high-variance bimodal population requires a large number of individual values compared to cutoff. Therefore, the number of samples required for confident failure detection depends on both the nature of the underlying distribution and the interpretive criteria. Further research is necessary to determine the true distributions of WBC-reduction process failure, as well as clinically relevant quality limits.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M R Adams, D M Fisher, L J Dumont, W H Dzik, W A Heaton. 2000. Detecting failed WBC-reduction processes: computer simulations of intermittent and continuous process failure.. https://doi.org/10.1046/j.1537-2995.2000.40121427.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Variable adhesion of different red blood cell products to activated vascular endothelium under flow conditions.

Red blood cells (RBCs) that have been stored prior to transfusion show increased adherence to vascular endothelium in vitro, which suggests a potential for stored blood transfusion to impede blood flow in some patients. Transfusion is often required in patients with sepsis or inflammation; however, whether activation of endothelium affects stored RBC-endothelial cell (EC) interactions is unknown. We investigated whether storage time and leukocyte content of RBC products influences the adhesion of RBCs to activated ECs. RBCs from nonleukocyte-reduced (S-RBCs), buffy-coat-poor (BCP-RBCs), and leukocyte-filtered (LF-RBCs) products and cultured EC layers were pretreated with endotoxin, tumor necrosis factor-alpha (TNF-alpha), or medium alone prior to perfusion of the RBCs across the EC layer in a continuous flow microchamber. After a single day of RBC storage, the number of adherent RBCs was increased in the endotoxin and TNF-alpha pretreated groups compared to the unactivated-control group. These differences were statistically significant for S-RBCs and LF-RBC products (P < 0.05). In contrast, there was no significant difference in RBC adherence to activated and unactivated endothelium at other time-points of RBC product storage. The strength of adhesion of stored RBCs from S-RBC products to activated ECs was not altered following treatment; however, endotoxin significantly increased the adhesive strength of LF-RBCs to endothelium. These results demonstrate that while fresh RBCs show increased adhesion to activated endothelium, storage of RBCs did not promote increased adhesion to activated endothelium. However, inflammatory conditions promote stronger adhesion of stored RBCs to ECs, which may contribute to impaired tissue perfusion in some transfusion recipients.

Blood Component Removal↗

Endotoxin apheresis for sepsis.

The principle use of apheresis in the treatment of sepsis may be summarized as the removal of toxic substances and the restoration of normal organs function. It is ideal to control the early phases of inflammatory cascade when treating sepsis by removing microbial components, such as endotoxin or peptidoglycan. This review discusses endotoxin apheresis with particular emphasis on treatment using polymyxin B immobilized fiber columns (Toraymyxin) which are used widely in Japan for endotoxin removal therapy in patients with septic shock. Lixelle and CTR which have recently been shown to remove circulating bacterial components are also included in this review.

Blood Component Removal↗