PubMed Health⌕ Search

PubMed · 11142810

[Implants such as artificial joints].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Matsushita, H Aoki, J Shimada. 2000-11-10. [Implants such as artificial joints].. https://pubmed.ncbi.nlm.nih.gov/11142810/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The new Frenchay artificial cervical joint: results from a two-year pilot study.

STUDY DESIGN: A clinical prospective observational cohort study of 15 patients undergoing cervical intervertebral disc replacement. OBJECTIVE: To assess the safety, clinical stability, and capacity of a newly designed cervical intervertebral disc replacement for preserving motion in the cervical spine of patients with degenerative disc disease. SUMMARY OF BACKGROUND DATA: Anterior cervical discectomy and interbody fusion results in loss of motion segments and there is evidence of accelerated degenerative changes occurring at adjacent levels. Intervertebral disc replacement may be a valid alternative to fusion. There is a need for cervical disc replacement to be evaluated in prospective studies before it can be adopted as an acceptable surgical technique. METHODS: The study enrolled 15 patients with cervical radiculopathy or myelopathy and radiologically confirmed cervical disc herniation or posterior vertebral body osteophytes. Eligibility for the study required that patients have either a previous adjacent-level surgical or congenital spinal fusion or radiologic evidence of adjacent-level degenerative disc disease. After decompressive surgery via an anterior approach, all 15 patients received the artificial joint. Follow-up visits were at set intervals and included clinical examination, radiologic assessment, and evaluation by patient-completed questionnaires. RESULTS: In all cases, the artificial joint maintained motion at the operative levels while reestablishing intervertebral height. The procedure was considered safe for experienced spine surgeons to perform, and the device was stable, with no dislocation of components or backing out of screws. Two screws broke, but without any consequence. Improvements in assessment scores were noted. CONCLUSIONS: Cervical intervertebral motion can be maintained with the new device, which is clinically stable. Meticulous attention must be paid to the surgical technique to maximize the chances of a good result. The pilot study was successful, although it has yet to be determined what conditions will benefit most from this technology.

Arthroplasty, Replacement↗

Changes in macrophage morphology and prolonged cell viability following exposure to polyethylene particulate in vitro.

The interaction of macrophages and ultra-high molecular weight polyethylene (PE) wear plays an important role in perpetuating chronic inflammation at the bone implant interface, leading to peri-implant osteolysis and mechanical failure of the implant. A model to study the interaction of human mature macrophages with orthopaedic biomaterial wear has been previously developed. With the use of the model, in this study, the mature human monocyte-derived macrophages (MDMs) were observed with light, fluorescent, and scanning electron microscopy (SEM), as well as transmission electron microscopy (TEM). The cell viability was investigated using calcein and ethidium staining. Following exposure to PE particulate, the morphology of the human MDMs was heterogeneous: rounded, flattened, and elongated. There was no morphological evidence of cytotoxicity or apoptosis. The MDM viability was not influenced by phagocytosis of PE particulate in a negative fashion. In fact, more prolonged cell viability was observed in the human MDMs exposed to PE particulate when compared to controls.

Arthroplasty, Replacement↗

The effect of particle wear debris on NFkappaB activation and pro-inflammatory cytokine release in differentiated THP-1 cells.

Orthopedic wear debris has been thought to be an important factor associated with osteolysis and loosening of total joint arthroplasties. Previous in vitro studies have reported that particles of wear debris induce the release of pro-inflammatory cytokines and other inflammatory mediators from macrophages and other cells. Several recent investigations, however, have suggested that the wear particles themselves may not be primarily responsible for the inflammatory cellular responses, but that the observed cytokine release in vitro may be caused by endotoxin adsorbed to commercially available particle preparations. The intracellular pathways involved in macrophage signal transduction also are poorly understood. The purposes of this study are to use isolated orthopedic wear debris particles to evaluate pro-inflammatory cytokine release and nuclear factor kappa B (NFkappaB) activation from macrophages. Cells from human monocyte/macrophage cell line (THP-1) were differentiated and incubated with particles of debris that had been isolated from a failed human total hip arthroplasty. The titanium-alloy particles did not evoke release of TNF-alpha or IL-1beta whereas lipopolysaccharide (LPS) or LPS-treated debris particles induced both TNF-alpha and IL-1beta. LPS-treated particles, but not particles alone, stimulated NFkappaB activation. Our results suggest that at the concentrations tested in this study, endotoxin-free wear debris particles may not themselves initiate inflammatory cellular responses in differentiated THP-1 cells. It is unclear whether adsorbed endotoxin is clinically associated with osteolysis and/or loosening in total joint arthroplasties, but several factors, including adsorbed endotoxin, need to be investigated to explore the cellular responses responsible for osteolysis and/or loosening.

Arthroplasty, Replacement↗