Abstract

A new interface combining phased arrays and echo-planar imaging (EPI) technologies was developed for two channel breast MR EPI applications. A detailed design for a dual-channel, EPI-compatible, phased array breast coil is described. EPI digital data multiplexing, signal controlling and sampling schemes are also presented. Results from breast phantoms and patients demonstrate a 55% improvement in signal-to-noise ratio when compared to a conventional two-loop, single channel coil configuration. This method can be easily expanded to a four or more channel, EPI-compatible, phased array system to improve field-of-view coverage and signal-to-noise ratio.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G X Shen, J Wu, F E Boada. 2000. Multiple channel phased arrays for echo planar imaging.. https://doi.org/10.1007/bf02678477

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗