PubMed Health⌕ Search

PubMed · 11157332

Age-related decrease in resting energy expenditure in sedentary white women: effects of regional differences in lean and fat mass.

Abstract

BACKGROUND: Lean mass and resting energy expenditure (REE) decrease with age. However, it is unknown whether age-related changes in regional lean and fat mass are responsible for the age-related decrease in REE. OBJECTIVE: Our objective was to determine how regional lean and fat mass vary with age and whether age is independently related to REE after adjustment for regional fat and lean mass. DESIGN: The study was a cross-sectional evaluation of 58 white women aged 23-77 y. Regional and whole-body lean and fat mass were measured by dual-energy X-ray absorptiometry, subcutaneous abdominal tissue (SAT) and intraabdominal adipose tissue (IAF) by computed tomography, and REE by ventilated-canopy indirect calorimetry. RESULTS: Independent of other significant correlates, age was significantly and independently associated with greater IAF (beta = 0.49) and less leg lean mass (beta = -0.35). IAF (r = -0.28) and IAF:SAT (r = -0.31) correlated negatively with REE. REE was negatively associated with greater age (beta = -0.42), independent of changes in lean and fat mass in different parts of the body. By contrast, trunk lean (beta = 0.27) and leg fat (beta = 0.27) mass were associated with greater REE independent of age and other body-composition variables. CONCLUSIONS: These results suggest that trunk lean mass (presumably primarily organ tissue) is relatively resistant to age-related changes in body composition, whereas muscle mass, especially leg muscle, tends to be lost. These data also suggest that the age-related decreases in REE are not fully explained by changes in body composition.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G R Hunter, R L Weinsier, B A Gower, C Wetzstein. 2001. Age-related decrease in resting energy expenditure in sedentary white women: effects of regional differences in lean and fat mass.. https://doi.org/10.1093/ajcn%2F73.2.333

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗