Evaluation of dissolution profiles using principal component analysis.

Abstract

The performance of principal component analysis (PCA) for the evaluation of dissolution profiles is examined and compared with other methods such as the similarity factor and the calculation of the area under the curve. Both simulated and real data from the pharmaceutical industry are used. The PCA scores plots of the dissolution curves provide information about the between- and within-batch variations. Differences in level or shape can be observed in the first two principal components (PCs). Irrelevant irregularities, which have a strong influence on the similarity factor, are neglected in PC1/PC2. To detect outliers in a set of dissolution curves, PCA was preferred above Hotelling's T2 test. In general, PCA is found to be a useful technique to examine dissolution data visually, but however, it does not contain criteria to decide if batches are similar or not. This can be done by combining PCA with the resampling with replacement or bootstrap method to construct confidence limits.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Adams, R De Maesschalck, B De Spiegeleer, Y Vander Heyden, J Smeyers-Verbeke, D L Massart. 2001-01-05. Evaluation of dissolution profiles using principal component analysis.. https://doi.org/10.1016/s0378-5173(00)00581-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of agitation force in dissolution test and mechanical destructive force in disintegration test.

The purpose of this study was to investigate the effect of the agitation force and mechanical destructive force on the drug dissolution of a tablet in the paddle rotation dissolution test and in the disintegration test. The agitation in the paddle method and the mechanical destructive force in the disintegration test were considered to be conclusive factors for drug dissolution. The dissolution rate of planar-constant-release tablets increased with increasing paddle rotation speed and increased with increasing distance from the center of the vessel bottom. Separately, the fluid resistance (agitation force) in the vessel was measured using a modified paddle method apparatus equipped with a fluid resistance sensor. The fluid resistance was 0.03 x 10(-3) N/(64 mm(2)) when the paddle rotation speed was 50 rpm at a position 4 mm away from the center. A considerable position-dependent change in agitation force intensity was seen with the fluid resistance sensor. The impulsive force (mechanical destructive force) in the disintegration test apparatus was measured using a modified basket-rack assembly with a strain gauge transducer. The fluid resistance was measured using the basket-rack assembly with a different sensor probe and amplifier. The impulsive force applied by the auxiliary disk was 0.31 N and the fluid resistance at the bottom of the basket-rack assembly was 1.66 x 10(-3) N/(64 mm(2)).

Solubility↗

Development of disintegrating multiple-unit tablets on a high-speed rotary tablet press.

Enteric coated bisacodyl pellets were compressed into divisible disintegrating tablets on a high speed rotary tablet press and investigated for pellet damages. The degree of pellet damages was examined via the bisacodyl dissolution during the acid treatment of' the drug release test for enteric coated articles according to USP 23. The damages depended on the type of filler-binder used and settings of the tablet press. Avicel PH 101 proved to be the most suitable filler-binder, effecting homogeneous distribution of the pellets within the tablets, as could be shown by image analysis of coloured pellets. The speed of the tablet press had noo influence on the pellet damages using Avicel PH 101 as a filler-binder, however, tablets containing 70% (w/w) of coated pellets did not fulfil the requirements of USP 23, despite optimum elasticity and coating thickness of a new Eudragit FS 30 D coating. Reducing the proportion of pellets to 60% per tablet, less than 10% of bisacodyl were released within 2 h during acid treatment thus fulfilling the requirements of the USP 23.

Solubility↗