PubMed Health⌕ Search

PubMed · 11199673

Defect morphology: effects on regenerative predictability and membrane selection.

Abstract

In clinical experience, guided tissue regeneration has been associated with complications, which include membrane exposure. The maintenance of a stable blood clot under the membrane is key to a successful regenerative outcome. This requires adequate membrane stabilization, tension-free suturing, and maintenance of a good vascular supply to the defect. Careful selection of defects after a thorough periodontal evaluation and modification of surgical techniques from those used for conventional resective procedures can lead to predictable outcomes for guided tissue regeneration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A del Castillo. 2000. Defect morphology: effects on regenerative predictability and membrane selection.. https://pubmed.ncbi.nlm.nih.gov/11199673/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mechanical stretch regimen enhances the formation of bioengineered autologous cardiac muscle grafts.

BACKGROUND: Surgical repair of congenital and acquired cardiac defects may be enhanced by the use of autologous bioengineered muscle grafts. These tissue-engineered constructs are not optimal in their formation and function. We hypothesized that a mechanical stretch regimen applied to human heart cells that were seeded on a three-dimensional gelatin scaffold (Gelfoam) would improve tissue formation and enhance graft strength. METHODS AND RESULTS: Heart cells from children undergoing repair of Tetralogy of Fallot were isolated and cultured. Heart cells were seeded on gelatin-matrix scaffolds (Gelfoam) and subjected to cyclical mechanical stress (n=7) using the Bio-Stretch Apparatus (80 cycles/minute for 14 days). Control scaffolds (n=7) were maintained under identical conditions but without cyclical stretch. Cell counting, histology, and computerized image analysis determined cell proliferation and their spatial distribution within the tissue-engineered grafts. Collagen matrix formation and organization was determined with polarized light and laser confocal microscopy. Uniaxial tensile testing assessed tissue-engineered graft function. Human heart cells proliferated within the gelatin scaffold. Remarkably, grafts that were subjected to cyclical stretch demonstrated increased cell proliferation and a marked improvement of cell distribution. Collagen matrix formation and organization was enhanced by mechanical stretch. Both maximal tensile strength and resistance to stretch were improved by cyclical mechanical stretch. CONCLUSION: The cyclical mechanical stretch regimen enhanced the formation of a three-dimensional tissue-engineered cardiac graft by improving the proliferation and distribution of seeded human heart cells and by stimulating organized matrix formation resulting in an order of magnitude increase in the mechanical strength of the graft.

Absorbable Implants↗

Tissue engineering of functional trileaflet heart valves from human marrow stromal cells.

BACKGROUND: We previously demonstrated the successful tissue engineering and implantation of functioning autologous heart valves based on vascular-derived cells. Human marrow stromal cells (MSC) exhibit the potential to differentiate into multiple cell-lineages and can be easily obtained clinically. The feasibility of creating tissue engineered heart valves (TEHV) from MSC as an alternative cell source, and the impact of a biomimetic in vitro environment on tissue differentiation was investigated. METHODS AND RESULTS: Human MSC were isolated, expanded in culture, and characterized by flow-cytometry and immunohistochemistry. Trileaflet heart valves fabricated from rapidly bioabsorbable polymers were seeded with MSC and grown in vitro in a pulsatile-flow-bioreactor. Morphological characterization included histology and electron microscopy (EM). Extracellular matrix (ECM)-formation was analyzed by immunohistochemistry, ECM protein content (collagen, glycosaminoglycan) and cell proliferation (DNA) were biochemically quantified. Biomechanical evaluation was performed using Instron(TM). In all valves synchronous opening and closing was observed in the bioreactor. Flow-cytometry of MSC pre-seeding was positive for ASMA, vimentin, negative for CD 31, LDL, CD 14. Histology of the TEHV-leaflets demonstrated viable tissue and ECM formation. EM demonstrated cell elements typical of viable, secretionally active myofibroblasts (actin/myosin filaments, collagen fibrils, elastin) and confluent, homogenous tissue surfaces. Collagen types I, III, ASMA, and vimentin were detected in the TEHV-leaflets. Mechanical properties of the TEHV-leaflets were comparable to native tissue. CONCLUSION: Generation of functional TEHV from human MSC was feasible utilizing a biomimetic in vitro environment. The neo-tissue showed morphological features and mechanical properties of human native-heart-valve tissue. The human MSC demonstrated characteristics of myofibroblast differentiation.

Absorbable Implants↗

Optimal biomaterial for creation of autologous cardiac grafts.

BACKGROUND: The optimal cardiac graft for the repair of congenital heart defects will be composed of autologous cells and will grow with the child. The biodegradable material should permit rapid cellular growth and delayed degradation with minimal inflammation. We compared a new material, epsilon-caprolactone-co-L-lactide sponge reinforced with knitted poly-L-lactide fabric (PCLA), to gelatin (GEL) and polyglycolic acid (PGA), which are previously evaluated materials. METHODS: Syngenic rat aortic smooth muscle cells (SMCs, 2x10(6)) were seeded onto GEL, PGA, and PCLA patches and cultured (n=11 per group). The DNA content in each patch was measured at 1, 2, and 3 weeks after seeding. Histological examination was performed 2 weeks after seeding. Cell-seeded patches were employed to replace a surgically created defect in the right ventricular outflow tract (RVOT) of rats (n=5 per group). Histology was studied at 8 weeks following implantation. RESULTS: In vitro studies showed that the DNA content increased significantly (P<0.05) in all patches between 1 and 3 weeks after seeding. Histology and staining SMCs for anti-alpha-smooth muscle actin (alphaSMA) revealed better growth of cells in the interstices of the grafts with GEL and PCLA than the PGA graft. In vivo studies demonstrated that seeded SMCs survived at least 8 weeks after the patch implantation in all groups. PCLA scaffolds were replaced by more cells with larger alphaSMA-positive areas and by more extracellular matrix with larger elastin-positive areas than with GEL and PGA. The patch did not thin and expanded significantly. The GEL and PGA patches thinned and expanded. All grafts had complete endothelialization on the endocardial surface. CONCLUSIONS: SMC-seeded biodegradable materials can be employed to repair the RVOT. The novel PCLA patches permitted better cellular penetration in vitro and did not thin or dilate in vivo and did not produce an inflammatory response. The cell-seeded PCLA patch may permit the construction of an autologous patch to repair congenital heart defects.

Absorbable Implants↗