PubMed Health⌕ Search

PubMed · 11219740

High sensitivity waveguide grating sensor based on radiative losses.

Abstract

A scheme of a waveguide sensor utilizing an output grating coupler with the grating length less than the coupling length is analyzed. This is the new method for the evaluation of average thickness of the adsorbed layer. This method, based on measurements of radiation loss coefficients, is proposed. Sensitivity limits of such a scheme are discussed. The new scheme has strong response on formation on the adsorbed layer and relatively weaker response on the fluctuations of temperature and analyte concentration. New possibilities for multiparameter sensing are shown.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Kochergin, I Avrutsky, Y Zhao. 2000. High sensitivity waveguide grating sensor based on radiative losses.. https://doi.org/10.1016/s0956-5663(00)00072-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques↗

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques↗

Water-soluble and optically pH-sensitive single-walled carbon nanotubes from surface modification.

There is great interest in using single-walled carbon nanotubes (SWNTs) as nanoscale probes and sensors in biological electronics and optical devices because the electronic and optical properties of SWNTs are extremely sensitive to the surrounding environments. A well-controlled modification of SWNT surfaces may provide unique interfaces that are sensitive to the biological variables such as pH, glucose, various ions and proteins. In this paper, we report a facile chemical routine to prepare water-soluble SWNTs that still retain their van Hove singularities after acid oxidative treatment. The aqueous solutions (0.03-0.15 mg/mL) are stable for more than a month. The solubility in water for as-treated SWNTs with surfaces modified by carboxylate groups provides us with a unique opportunity to reveal the relationship of the SWNT electronic and optical properties with pH. Here we present the first observation that after surface modification with carboxylate groups, the optical absorption of the first interband transition of as-treated water-soluble semiconducting SWNTs reversibly responds to the pH change in aqueous solutions. Our results indicate that surface modification of SWNTs is a promising way for preparing chemically selective SWNT interfaces, which may open new exciting opportunities for various applications.

Biosensing Techniques↗