PubMed Health⌕ Search

PubMed · 11223152

Implementation of a dynamic platform-independent DICOM-server.

Abstract

Hospital-wide image and patient data transfer within heterogeneous hard- and software infrastructures can be facilitated by using standardized communication protocols and data formats such as digital imaging and communications in medicine (DICOM). Each DICOM application entity (AE) usually provides a static and fixed set of services according to its functionality. However, certain security concepts, changing demands of medical users, or restricted hardware capabilities may be more easily addressed by applications that dynamically provide variable subsets of DICOM services. In a new approach, an object-oriented DICOM server framework was developed that served as a basis for assembling various DICOM applications. These applications may be set up dynamically to offer variable subsets of services at runtime, similar to "plug-ins". The framework was designed and implemented in Java in order to provide low-cost platform-independent solutions. As an example, a DICOM server was implemented and tested in a clinical application providing access to MR and CT images through a Java/DICOM viewer. Data retrieval was optimized by storing parts of the image acquisition and patient data into a relational database.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Bernarding, A Thiel, I Decker, T Tolxdorff. 2001. Implementation of a dynamic platform-independent DICOM-server.. https://doi.org/10.1016/s0169-2607(00)00103-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗