Virtual fluoroscopy: computer-assisted fluoroscopic navigation.

Abstract

STUDY DESIGN: In vitro accuracy assessment of a novel virtual fluoroscopy system. OBJECTIVES: To investigate a new technology combining image-guided surgery with C-arm fluoroscopy. SUMMARY OF BACKGROUND DATA: Fluoroscopy is a useful and familiar technology to all musculoskeletal surgeons. Its limitations include radiation exposure to the patient and operating team and the need to reposition the fluoroscope repeatedly to obtain surgical guidance in multiple planes. METHODS: Fluoroscopic images of the lumbar spine of an intact, unembalmed cadaver were obtained, calibrated, and saved to an ). A was used for the sequential insertion of a light-emitting diode-fitted probe into the pedicles of L1-S1 bilaterally. The trajectory of a "virtual tool" corresponding to the tracked tool was overlaid onto the saved fluoroscopic views in real time. Live fluoroscopic images of the inserted pedicle probe were then obtained. Distances between the tips of the virtual and fluoroscopically displayed probes were quantified using the image-guided computer's measurement tool. Trajectory angle differences were measured using a standard goniometer and printed copies of the workstation computer display. The surgeon's radiation exposure was measured using thermolucent dosimeter rings. RESULTS: Excellent correlation between the virtual fluoroscopic images and live fluoroscopy was observed. Mean probe tip error was 0.97 +/- 0.40 mm. Mean trajectory angle difference between the virtual and fluoroscopically displayed probes was 2.7 degrees +/- 0.6 degrees. The thermolucent dosimeter rings measured no detectable radiation exposure for the surgeon. CONCLUSIONS: Virtual fluoroscopy offers several advantages over conventional fluoroscopy while providing acceptable targeting accuracy. It enables a single C-arm to provide real-time, multiplanar procedural guidance. It also dramatically reduces radiation exposure to the patient and surgical team by eliminating the need for repetitive fluoroscopic imaging for tool placement.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K T Foley, D A Simon, Y R Rampersaud. 2001-02-15. Virtual fluoroscopy: computer-assisted fluoroscopic navigation.. https://doi.org/10.1097/00007632-200102150-00009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An analysis of the strengths and weaknesses of endoscopic and radiological investigations of velopharyngeal incompetence based on a 20 year experience of simultaneous recording.

The simultaneous recording of nasopharyngoscopy and video fluoroscopy allows a comparison to be made of their reliability under various circumstances. While the monocular view and the number of optical fallacies make measurement from endoscopy impossible, radiological views can also be shown to be fallacious, and all measurements should be treated with caution. However, through clinical observation the variability of the final dimensions of tissues raised to treat velopharyngeal incompetence can be roughly gauged. Indeed, the need for more accurate measurement awaits the arrival of a predictable procedure to allow fine tuning of surgery. Simultaneous recording has permitted improved clarity of interpretation and accuracy of measurement in some cases. The chief gain from investigations over the past 30 years has been in the considerably increased understanding of the range of normal and pathological morphology that must be taken into account in surgical treatment.

Fluoroscopy↗

Intraoperative accuracy evaluation of virtual fluoroscopy--a method for application in computer-assisted distal locking.

Virtual fluoroscopy integrates intraoperative C-arm fluoroscopy as an imaging modality for surgical navigation. In the operating room, the conditions for application of virtual fluoroscopy may be impaired. In such situations, the surgeon is interested in an intraoperative check to decide whether the accuracy available is sufficient to perform the scheduled procedure. The test principle is to include an artificial landmark within the fluoroscopic images acquired for virtual fluoroscopy. As this landmark is fixed outside the patient, it can be touched with the referenced tool prior to performing the procedure. A mismatch between the actual tool position at the landmark and the virtual tool position as visualized on the computer screen allows estimation of the system's accuracy. The principle described was designed for detection of inaccuracies resulting from input of nonoptimal data to the navigation system. The method was successfully applied during computer-assisted distal locking of intramedullary implants, and the test principle might be adapted for other applications of virtual fluoroscopy.

Fluoroscopy↗