PubMed Health⌕ Search

PubMed · 11224921

Biodegradable polymer scaffolds with well-defined interconnected spherical pore network.

Abstract

Scaffolding plays pivotal role in tissue engineering. In this work, a novel processing technique has been developed to create three-dimensional biodegradable polymer scaffolds with well-controlled interconnected spherical pores. Paraffin spheres were fabricated with a dispersion method, and were bonded together through a heat treatment to form a three-dimensional assembly in a mold. Biodegradable polymers such as PLLA and PLGA were dissolved in a solvent and cast onto the paraffin sphere assembly. After dissolving the paraffin, a porous polymer scaffold was formed. The fabrication parameters were studied in relation to the pore shape, interpore connectivity, pore wall morphology, and mechanical properties of the polymer scaffolds. The compressive modulus of the scaffolds decreased with increasing porosity. Longer heat treatment time of the paraffin spheres resulted in larger openings between the pores of the scaffolds. Foams of smaller pore size (100-200 microm) resulted in significantly lower compressive modulus than that of larger pore sizes (250-350 or 420-500 microm). The PLLA foams had a skeletal structure consisting of small platelets, whereas PLGA foams had homogeneous skeletal structure. The new processing technique can tailor the polymer scaffolds for a variety of potential tissue engineering applications because of the well-controlled architecture, interpore connectivity, and mechanical properties.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P X Ma, J W Choi. 2001. Biodegradable polymer scaffolds with well-defined interconnected spherical pore network.. https://doi.org/10.1089/107632701300003269

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Plug migration and cement mantle assessment in total hip replacement.

We reviewed a series of consecutive total hip replacements with cemented femoral components. Modern cementing techniques were followed in all cases, but two different medullary plugs were used-one was polyethylene and the other bioabsorbable gelatin. Cement mantle quality and plug migration were assessed by three different observers (X, Y, and Z); their findings did not agree. This was particularly evident when the cement mantles were assessed. There was a better cement mantle grading and less distal migration with polyethylene plugs, although there was no significant statistical difference between the two groups.

Absorbable Implants↗

First evidence that bone marrow cells contribute to the construction of tissue-engineered vascular autografts in vivo.

BACKGROUND: Materials commonly used to repair complex cardiac defects lack growth potential and have other unwanted side effects. We designed and tested a bone marrow cell (BMC)-seeded biodegradable scaffold that avoids these problems. METHODS AND RESULTS: To demonstrate the contribution of the BMCs to histogenesis, we labeled them with green fluorescence, seeded them onto scaffolds, and implanted them in the inferior vena cava of dogs. The implanted grafts were analyzed immunohistochemically at 3 hours and subsequently at 2, 4, and 8 weeks after implantation using antibodies against endothelial cell lineage markers, endothelium, and smooth muscle cells. There was no stenosis or obstruction caused by the tissue-engineered vascular autografts (TEVAs) implanted into the dogs. Immunohistochemically, the seeded BMCs expressing endothelial cell lineage markers, such as CD34, CD31, Flk-1, and Tie-2, adhered to the scaffold. This was followed by proliferation and differentiation, resulting in expression of endothelial cells markers, such as CD146, factor VIII, and CD31, and smooth muscle cell markers, such as alpha-smooth muscle cell actin, SMemb, SM1, and SM2. Vascular endothelial growth factor and angiopoietin-1 were also produced by cells in TEVAs. CONCLUSIONS: These results provide direct evidence that the use of BMCs enables the establishment of TEVAs. These TEVAs are useful for cardiovascular surgery in humans and especially in children, who require biocompatible materials with growth potential, which might reduce the instance of complications caused by incompatible materials and lead to a reduced likelihood of further surgery.

Absorbable Implants↗

Long-term study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits.

Biodegradation of hydroxyapatite (HA)/poly(L-lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u-HA) or calcined HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA containing 30 or 40% (w/w) HA were implanted in the distal femur of 21 rabbits, and specimens were examined by light microscopy, scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM) 2-4 years later. For u-HA/PLLA, trabecular bone bonding directly onto the rod was maintained for up to 2 years. By 3 years, surface collapse had begun, and the implants were shrinking. By 4 years, they had shrunk further, with complete bone encapsulation. The u-HA particles were small and needle shaped in the peripheries, and TEM confirmed their resorption. The cross-sectional area after 4 years decreased by 23.3+/-8.4%. The mean ratio of bony ingrowth to the initial cross-sectional area around the shrunken rods was 6.7+/-1.3 %. The viscosity molecular weight of PLLA reduced from 2 x 10(5) to less than 1 x 10(3). Thus, most of the PLLA had released from the rods. The c-HA/PLLA implants also showed good osteoconductivity, but shrinkage and infiltration of histiocytes were less. No osteolytic or osteoarthritic changes were found.

Absorbable Implants↗