PubMed Health⌕ Search

PubMed · 11227069

Validation of array-based gene expression profiles by real-time (kinetic) RT-PCR.

Abstract

We evaluated real-time (kinetic) reverse transcription-polymerase chain reaction (RT-PCR) to validate differentially expressed genes identified by DNA arrays. Gene expression of two keratinocyte subclones differing in the physical state of human papillomavirus (episomal or integrated) was used as a model system. High-density filter arrays identified 444 of 588 genes as either negative or expressed with less than twofold difference, and the other 144 genes as expressed uniquely or with more than twofold difference between the two subclones. Real-time RT-PCR used LightCycler-based SYBR Green I dye detection and melting curve analysis to validate the relative change in gene expression. Real-time RT-PCR confirmed the change in expression of 17 of 24 (71%) genes identified by high-density filter arrays. Genes with strong hybridization signals and at least twofold difference were likely to be validated by real-time RT-PCR. This data suggests that (i) both hybridization intensity and the level of differential expression determine the likelihood of validating high-density filter array results and (ii) genes identified by DNA arrays with a two- to fourfold difference in expression cannot be eliminated as false nor be accepted as true without validation. Real-time RT-PCR based on LightCycler technology is well-suited to validate DNA array results because it is quantitative, rapid, and requires 1000-fold less RNA than conventional assays.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M S Rajeevan, S D Vernon, N Taysavang, E R Unger. 2001. Validation of array-based gene expression profiles by real-time (kinetic) RT-PCR.. https://doi.org/10.1016/s1525-1578(10)60646-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗