Cardiac output-based versus empirically programmed AV interval--how different are they?

Abstract

AIMS: To compare empirically programmed and cardiac output-based programming of atrioventricular (AV) interval in patients with dual chamber pacemakers. METHODS AND RESULTS: In 19 patients with implanted dual chamber pacemakers due to AV block but otherwise normal hearts, cardiac output was assessed using an impedance cardiography device. In all patients, the AV interval had been previously programmed empirically by an experienced cardiologist. Cardiac output was estimated at AV intervals from 50 to 250 ms during VDD pacing. AV intervals adjusted by serial cardiac output estimations caused a rise in cardiac output in 84% of patients. The maximal achievable cardiac output was greater by 12% +/- 8% (range 0-32%), P < 0.001, than was observed with empirically programmed AV intervals. CONCLUSIONS: In patients with dual chamber pacemakers due to AV block and otherwise normal hearts, empirically selected AV intervals may lead to compromise of cardiac haemodynamics. Optimal AV intervals may be selected by serial cardiac output measurements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Crystal, I E Ovsyshcher. 1999. Cardiac output-based versus empirically programmed AV interval--how different are they?. https://doi.org/10.1053/eupc.1998.0029

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biventricular repair of right-dominant complete atrioventricular canal defect.

Complete atrioventricular (AV) canal defects usually have right and left valve components of approximately equal size, although unbalanced forms do occur. Optimal management of unbalanced AV canal defects is controversial, with no proven guidelines for choosing between biventricular repair and univentricular palliation. We describe successful biventricular repair of a right-dominant unbalanced AV canal with severe left AV valve stenosis. This case illustrates that severely unbalanced AV canal defects can be repaired successfully by tailoring the AV valve to distribute it equally between the ventricles, The increase in left ventricular volume after surgery exceeded prediction based on conformational change alone.

Atrioventricular Node↗

Junctional rhythm in hypertrophic cardiomyopathy: a case report.

We observed a case of a 47-year-old male patient with hypertrophic cardiomyopathy and family history of sudden death. During cardiac catheterization, the patient presented spontaneous intermittent atrioventricular junctional rhythm without significant changes related to sinus heart rate. The gradient was absent with sinus beats, but the junctional rhythm induced the appearance of a left ventricular-aorta gradient, with parallel reduction of aortic pressure from 156 to 120 mm Hg. Subsequently, a couple of pre-mature ventricular beats induced an important post-extrasystolic potentiation of the gradient, followed in the last beats by sinus rhythm with disappearance of the gradient. Our case suggests that the decrease of left ventricular volume, due to the absence of an effective atrial systole, leads to left ventricular increased gradient, not imputable to an increased inotropic effect or heart rate modifications but to the decrease of pre-load.

Atrioventricular Node↗