PubMed Health⌕ Search

PubMed · 11240855

Quantitative serial sectioning analysis.

Abstract

A method for serial sectioning is presented that allows one to take about 20 sections per hour with spacings in the range 1-20 microm between sections. The alignment of the cross-sections is done with a linear variable differential transformer; it is thus independent of the microstructure of the sample and does not rely upon markers implanted in the sample. The alignment errors as well as tilts and rotation errors between sections associated with the new method are found to be negligible. Once all the sections are captured in a computer a three-dimensional image can be constructed. This image can be viewed interactively and rotated, thus allowing the direct observation of three-dimensional shapes. It can further be used to determine a vast array of microstructural parameters including those that cannot be determined from planar sections. The technique is illustrated through the reconstruction of the microstructure of a cast standard aluminium alloy specimen.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Alkemper, P W Voorhees. 2001. Quantitative serial sectioning analysis.. https://doi.org/10.1046/j.1365-2818.2001.00832.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Osseointegration of hydroxyapatite-coated and noncoated Ti6Al4V implants in the presence of local infection: a comparative histomorphometrical study in rabbits.

A study was designed to investigate the osseointegration of titanium implants, either noncoated or coated with hydroxyapatite (HA), into rabbit tibiae in the presence of local infection compared with osseointegration in the absence of local infection. HA-coated or noncoated Ti cylinders were implanted into both tibiae of 32 rabbits (New Zealand Whites). Before implantation the left tibia was contaminated with different quantities of Staphylococcus aureus (10(2)-10(5) CFU). Four weeks after surgery the tibiae were explanted and prepared for microbiological and histomorphometrical examination. Histomorphometrical data, as a representation of implant fixation, were obtained by measuring the percentage of bone around the implants (within a radius of 1 mm from the outer diameter of the implants) and the percentage of the circumference of the implant that was in direct contact with bone. Histomorphometry revealed, in particular for the HA implants, a relationship between the inoculum concentration and/or the presence or absence of infection with the bone contact at the distal implant side. This confirms a relationship between peri-implant infection and bone contact or remodeling. HA-coated implants developed, in the presence of bacteria, more easily a more severe infection than noncoated Ti implants, and we show in the present study that local infection will influence histomorphometrical parameters (bone-implant contact) that determine implant fixation. Precautions to prevent contamination (asepsis) and/or infection (perioperative antibiotics) are even more important for the highly biocompatible HA-coated implant.

Alloys↗

Percutaneous left atrial appendage transcatheter occlusion to prevent stroke in high-risk patients with atrial fibrillation: early clinical experience.

BACKGROUND: Thromboembolism due to atrial fibrillation (AF) is a frequent cause of stroke. More than 90% of thrombi in AF form in the left atrial appendage (LAA). Obliteration of the appendage may prevent embolic complications. METHODS AND RESULTS: We evaluated the feasibility and safety of implanting a novel device for percutaneous left atrial appendage transcatheter occlusion (PLAATO). LAA occlusion using the PLAATO system was attempted in 15 patients with chronic AF at high risk for stroke, who are poor candidates for long-term warfarin therapy. The implant consists of a self-expanding nitinol cage covered with a polymeric membrane (ePTFE). The LAA was successfully occluded in 15/15 patients (100%). Angiography and transesophageal echocardiography (TEE) during the procedure showed that the device was well-seated in all patients and that there was no evidence of perforation, device embolization, or interference with surrounding structures. In 1 patient, the first procedure was complicated by a hemopericardium, which occurred during LAA access. A second attempt 30 days later was successful with no untoward sequela. No other complications occurred. At 1-month follow-up, chest fluoroscopy and TEE revealed continued stable implant position with smooth atrial-facing surface and no evidence of thrombus. CONCLUSIONS: Thus, transcatheter closure of the LAA is feasible in humans. This novel implant technology may be appropriate for patients with AF who are not suitable candidates for anticoagulation therapy. Further trials are needed to show the long-term safety and its efficacy in reducing stroke.

Alloys↗

Proliferation and differentiation of rat calvarial osteoblasts on type I collagen-coated titanium alloy.

Several attempts have been made to improve osseointegration of titanium alloy as an implant material by modification of its surface. In the present study, proliferation, differentiation, and mineralization of osteoblasts on type I collagen-coated Ti6Al4V were investigated. The activity of alkaline phosphatase and the accumulation of calcium by osteoblasts grown on titanium alloy were significantly higher compared to cells grown on polystyrene. Precoating of the implant surface with type I collagen did not extensively affect proliferation, the activity of alkaline phosphatase, collagen synthesis, calcium accumulation, or the mRNA levels for collagen I alpha1, osteopontin, osteocalcin, MMP-2, and TIMP-2. Maximum collagen synthesis by osteoblasts was observed at day 4 of culture independent of the type of implant material. The specific activity of alkaline phosphatase reached its maximum at day 18 of culture. Accumulation of calcium and elevated mRNA levels for osteocalcin were found at day 22. These results indicate that collagen-coating alone is not sufficient to accelerate differentiation of rat calvarial osteoblasts on Ti6Al4V.

Alloys↗