Valve replacement--a perspective.

Abstract

Several potential hazards in the evaluation of patients with valve replacement are emphasized. A more uniform method of analysis of data is urgently needed. In the symptomatically disabled patient aortic and mitral valve replacement have improved both the quality of life and the length of life, provided that the disease is not far advanced. Anticoagulation with sodium warfarin is still needed in patients with prosthetic valves. Many important questions, including those related to ventricular function and choice of prosthetic devices, remain unanswered. The cost-benefit ratio and a weighting of various complications of valve replacement should be assessed. Many factors have to be taken into account before considering valve replacement early in the course of the patient's disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S H Rahimtoola. 1975. Valve replacement--a perspective.. https://doi.org/10.1016/0002-9149(75)90063-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Rösch-Uchida transjugular liver access set--evaluation by CT and its clinical application].

Appropriateness of the Rösch-Uchida transjugular liver access set designed for TIPSS procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe.

Evaluation Studies as Topic

[Testing an ultrasonic scanner for determination of urinary bladder volume].

Bladderscan BVI 2000 is a portable ultrasound scanner, specially constructed for determination of bladder volume. We have tested this scanner for accuracy, systematic errors and the training required to use it. The bladder volumes measured by ultrasound scanning were compared with the true volumes. Fifty-six measurements were made. We found the accuracy of BVI 2000 sufficient to determine bladder volumes as either small or large. We found no systematic errors. No special training is required to use the scanner. The device is thus useful in most clinical situations when greater accuracy than indicated here is not necessary.

Evaluation Studies as Topic