Validated HPLC method for quantifying permethrin in pharmaceutical formulations.

Abstract

An isocratic HPLC method for permethrin determination in raw material and pharmaceutical presentations as lotion and shampoo has been developed and validated following ICH recommendations. Cis and trans- isomers, impurities and degradation products are well separated. The chromatographic analysis were performed on a 4 microm particle C-18 Nova-Pak (Waters, Madrid, Spain) column (15 x 0.39 cm) kept in a Biorad column oven at 35 degrees C. Mobile phase consisted of methanol--water (78:22, v/v) at a flow rate of 1 ml/min. UV detection was performed at 272 nm and peaks were identified with retention times as compared with standards and confirmed with characteristic spectra using the photodiode array detector.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E García, A García, C Barbas. 2001. Validated HPLC method for quantifying permethrin in pharmaceutical formulations.. https://doi.org/10.1016/s0731-7085(00)00544-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of free and total (free plus protein-bound) melatonin in plasma and cerebrospinal fluid by high-performance liquid chromatography with fluorescence detection.

A simple, sensitive and accurate method for the estimation of free and total (free plus protein-bound) melatonin (MLT) in human plasma and cerebrospinal fluid (CSF) is described. Via Chem-Elut cartridges, free and total MLT (the latter obtained after a deproteinization step) were quantified in dichloromethane-extracted samples and analyzed in one chromatographic run by high-performance liquid chromatography (HPLC) with fluorimetric detection. The column used was an Extrasil ODS-2 (3 microm, 150 x 4.6 mm I.D.), while the mobile phase consisted of 75 mM sodium acetate-acetonitrile (72:28, v/v) (pH 5.0). Repeatability and reproducibility of the method were 3.24 and 9.4%, respectively. The recovery of melatonin from plasma and CSF was 99.9+/-4.0% for non-deproteinized samples and 93.2+/-4.8% for deproteinized samples. The detection limit of the assay was 0.5 pg/ml. In human plasma, the mean+/-SD concentrations in the darkness period were 23.18+/-7.44 pg/ml for free melatonin and 82.5+/-36.48 pg/ml for total melatonin, while the lowest concentrations detected during daytime were 2.23+/-2.22 and 7.40+/-5.68 pg/ml, respectively. Detection of MLT in CSF was 5.01+/-2.31 and 28.55+/-6.95 pg/ml for the free and total fraction, respectively.

Chromatography, High Pressure Liquid↗

Intact glucosinolate analysis in plant extracts by programmed cone voltage electrospray LC/MS: performance and comparison with LC/MS/MS methods.

We present a comprehensive, sensitive, and highly specific negative ion electrospray LC/MS method for identifying all structural classes of glucosinolates in crude plant extracts. The technique is based on the observation of simultaneous maxima in the abundances of the m/z 96 and 97 ions, generated by programmed cone voltage fragmentation, in the mass chromatogram. The abundance ratios lie in the range 1:2-1:4 ([m/z 96]/[m/z 97]). Examination of the corresponding full-scan mass spectra allows individual glucosinolates of all structural classes to be identified rapidly and with confidence. The use of linearly programmed cone voltage fragmentation enhances characteristic fragment ions without compromising the abundance of the analytically important [M - H]- ion and its associated (and analytically useful) sulfur isotope peaks. Detection limits are in the low nanogram range for full-scan, programmed cone voltage spectra. Comparison of the technique with LC/MS/MS methods (product ion, precursor ion, and constant neutral loss scans) has shown that the sensitivity and selectivity of the programmed cone voltage method is superior. Data obtained on a variety of plant extracts confirmed that the methodology was robust and reliable.

Chromatography, High Pressure Liquid↗

Synthesis and characterization of a collagen model delta-O-phosphohydroxylysine-containing peptide.

The existence of delta-O-phosphohydroxylysine (HylP) residues in collagen has been reported. However, such phosphorylated residues have not been isolated nor has their location within the protein sequence been identified. To develop the analytical chemistry necessary for the identification of HylP in proteins, a model HylP-containing peptide, Phe-dl-HylP-Gly-Gln-Pro-Ala-Ile-Gly-Phe (I), was synthesized. The peptide was assembled using 9-fluorenylmethyloxycarbonyl (Fmoc)-based solid-phase synthesis; N(alpha)-Fmoc-dl-hydroxy-dl-Lys(N(epsilon)-tert-butyloxycarbonyl)-OH was used to incorporate Hyl, and global phosphitylation/oxidation was used to introduce the phosphate group. The pK(a2) of the phosphate group, as determined using 31P NMR, was 5.6. Phosphoamino acid analysis of I was performed using either dabsyl chloride or phenylisothiocyanate derivatization followed by microbore reversed-phase HPLC separation of N(alpha, epsilon)-didabsyl-HylP or N(alpha, epsilon)-diphenylthiocarbamyl-HylP. HylP was found to be relatively resistant to acid hydrolysis, allowing for its quantitation. Solid-phase Edman degradation of I was used for positive identification of N(alpha)-phenylthiohydantoin-N(epsilon)-phenylthiocarbamyl-HylP. The masses of the phenylthiohydantoin and dabsyl derivatives of HylP were confirmed by electrospray ionization triple-quadrupole (ESI-MS). Peptide I was positively identified as a phosphopeptide by ESI-MS/precursor-ion scanning. Low-energy ESI-MS/MS confirmed the position of HylP within the sequence of I. Phosphorylation of Hyl led to complete resistance of I to lysine-specific endopeptidases.

Chromatography, High Pressure Liquid↗