PubMed Health⌕ Search

PubMed · 11252801

Flow cytometric platform for high-throughput single nucleotide polymorphism analysis.

Abstract

We have developed a rapid, cost-effective, high-throughput readout for single nucleotide polymorphism (SNP) genotyping using flow cytometric analysis performed on a Luminex 100 flow cytometer. This robust technique employs a PCR-derived target DNA containing the SNP, a synthetic SNP-complementary ZipCode-bearing capture probe, a fluorescent reporter molecule, and a thermophilic DNA polymerase. An array of fluorescent microspheres, covalently coupled with complementary ZipCode sequences (cZipCodes), was hybridized to the reaction products and sequestered them for flow cytometric analysis. The single base chain extension (SBCE) reaction was used to assay 20 multiplexed SNPs for 633 patients in 96-well format. Comparison of the microsphere-based SBCE assay results to gel-based oligonucleotide ligation assay (OLA) results showed 99.3% agreement in genotype assignments. Substitution of direct-labeled R6G dideoxynucleotide with indirect-labeled phycoerythrin dideoxynucleotide enhanced signal five- to tenfold while maintaining low noise levels. A new assay based on allele-specific primer extension (ASPE) was validated on a set of 15 multiplexed SNPs for 96 patients. ASPE offers both the advantage of streamlining the SNP analysis protocol and the ability to perform multiplex SNP analysis on any mixture of allelic variants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D Taylor, D Briley, Q Nguyen, K Long, M A Iannone, M S Li, F Ye, A Afshari, E Lai, M Wagner, J Chen, M P Weiner. 2001. Flow cytometric platform for high-throughput single nucleotide polymorphism analysis.. https://doi.org/10.2144/01303dd04

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Real-time quantitation of HIV-1 p24 and SIV p27 using fluorescence-linked antigen quantification assays.

We developed fluorescence-linked antigen quantification (FLAQ) assays for HIV-1 and SIV antigen quantitation. The assays utilize polystyrene microspheres coated with monoclonal antibodies against HIV-1 Gag p24 or SIV Gag p27, which are incubated with unknown samples, flourochrome-conjugated detector antibody, and lysing agent. The fluorescence of individual microspheres is measured using flow cytometry. The speed, simplicity, and wide dynamic range of FIAQ assays makes them superior to enzyme-linked immunosorbent assays for many applications performed in research laboratories.

Flow Cytometry↗

Intravenous immunoglobulin-induced panel reactive antibody A reduction: not all preparations are created equal.

BACKGROUND: Use of intravenous (IV) immunoglobulin (Ig) to obtain panel reactive antibody (PRA) A reduction in sensitized patients has been widely reported. Because no IVIg preparation is formulated specifically for this purpose, the authors have sought to determine whether, through laboratory testing, they could guide the rational choice of product for clinical use. METHODS: Using a flow cytometric approach, the authors have quantitatively determined the capacity of 22 different IVIg preparations to cause PRA reduction. RESULTS: IVIg preparations showed considerable variability in their individual capacity to reduce serum PRA. Protein-A pretreatment of IVIg preparations was found to reduce their capacity to cause PRA reduction. CONCLUSION: Laboratory screening of IVIg preparations provides a rational basis for the selection of product for administration to patients in whom the aim is to produce a PRA reduction. Experiments involving protein-A treatment of IVIg preparations indicate that immunoglobulin G is the principal factor involved in the abrogation of serum reactivity.

Flow Cytometry↗