Soil solution extraction techniques for microbial ecotoxicity testing: a comparative evaluation.

Abstract

The suitability of two different techniques (centrifugation and Rhizon sampler) for obtaining the interstitial pore water of soil (soil solution), integral to the ecotoxicity assessment of metal contaminated soil, were investigated by combining chemical analyses and a luminescence-based microbial biosensor. Two different techniques, centrifugation and Rhizon sampler, were used to extract the soil solution from Insch (a loamy sand) and Boyndie (a sandy loam) soils, which had been amended with different concentrations of Zn and Cd. The concentrations of dissolved organic carbon (DOC), major anions (F- , CI-, NO3, SO4(2-)) and major cations (K+, Mg2+, Ca2+) in the soil solutions varied depending on the extraction technique used. Overall, the concentrations of Zn and Cd were significantly higher in the soil solution extracted using the centrifugation technique compared with that extracted using the Rhizon sampler technique. Furthermore, the differences observed between the two extraction techniques depended on the type of soil from which the solution was being extracted. The luminescence-based biosensor Escherichia coli HB101 pUCD607 was shown to respond to the free metal concentrations in the soil solutions and showed that different toxicities were associated with each soil, depending on the technique used to extract the soil solution. This study highlights the need to characterise the type of extraction technique used to obtain the soil solution for ecotoxicity testing in order that a representative ecotoxicity assessment can be carried out.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Tiensing, S Preston, N Strachan, G I Paton. 2001. Soil solution extraction techniques for microbial ecotoxicity testing: a comparative evaluation.. https://doi.org/10.1039/b007851o

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate.

There is an increasing interest in new strategies for replacing animal tests in research. The use of cell cultures and integrated electrodes is seen as a promising alternative that could potentially solve this problem. In this work, we present a L-glutamate sensor based on a bienzyme redox hydrogel, capable of detecting the release of this excitatory neurotransmitter from adherently growing cells upon stimulation. The low working potential required for the operation of the sensor decreases the possibility of interference by easily oxidizable compounds always present in complex biological samples. A low detection limit of 0.5 microM L-glutamate, a response time of about 35 s, and a linear range of up to 60 microM are the main characteristics of the sensor. The system has been successfully employed to monitor the release of l-glutamate from HN10 and C6 cells upon stimulation with K(+)-ions. The developed integrated electrochemical platform will be used in future for drug screening and potentially for replacing animal models in neurological experiments.

Biological Assay↗

Engineered Saccharomyces cerevisiae strain BioS-1, for the detection of water-borne toxic metal contaminants.

Saccharomyces cerevisiae responds to extracellular toxic stimuli by increasing intracellular cyclic AMP levels, leading to activation of a cAMP-dependent protein kinase, protein kinase A (PKA). Activated PKA phosphorylates downstream substrates, including specific DNA-binding proteins, to turn off the expression of most or all of the yeast genes. Such cAMP-PKA-mediated inhibition of gene expression in response to toxic stimuli appears to be unique to S. cerevisiae. For instance, in mammalian cells, the cAMP-PKA signaling pathway is rather responsive to growth factors and hormones in addition to being primarily involved in the activation of gene expression. Activation of gene expression by the cAMP-PKA pathway in mammalian cells is due mainly to the presence of cAMP-response elements (CREs) located in the promoters of many mammalian genes, and the expression of PKA-responsive stimulatory transcription factor CRE-binding protein, commonly referred as CREBP, which binds to the CREs. Thus, activation of the cAMP-PKA signaling pathway results in the phosphorylation of CREBP by PKA, and phosphorylated CREBP transactivates specific gene expression by interacting with the cognate CRE. Based on these findings, we sought to engineer a yeast-based biosensor, in which the stress-sensing cAMP-PKA pathway of yeast is coupled to the mammalian CREBP-CRE-stimulated gene expression pathway, which drives the expression of a reporter protein, such as green fluorescent protein (GFP). As a primary step toward the development of this biosensor, we engineered a yeast strain, BioS-1, by genetically altering YPH 501, a wild-type strain of S. cerevisiae, to express human CREBP and human CRE promoter-driven GFP. Exposure of BioS-1 to varying concentrations of As3+, Fe2+, Pb2+, and Cd2+ elicits concentration-dependent expression of the GFP reporter that can be easily monitored by the fluorescence emitted by GFP. The results also indicate that the engineered BioS-1 yeast cells can detect 2.5 ppm of these toxic metals and report it through the expression of GFP within 3 h. The results presented herein demonstrate that this engineered yeast strain can detect metal toxicants and can validate the use of this prototypic yeast strain to develop a biosensor that can be used to detect and monitor cytotoxic water-borne toxic heavy metals.

Biological Assay↗

An integrated mini biosensor system for continuous water toxicity monitoring.

An integrated water toxicity monitoring system that uses recombinant bioluminescent bacteria was successfully developed for the continuous monitoring and classification of toxicities present in water. This system consists of four channels arranged horizontally inside of a cylinder, with each channel having two small bioreactors that are vertically connected to each other to maintain a separation of the culture reactor from test reactor. This system is easily handled and installed, making its application in the field a potential reality. As well, it performed stably and continuously due to the vertical separation of the culture reactor from the test reactor and a long term operation was also performed because of its small working volume, i.e., only 1 ml for the 1st bioreactor and 2 ml for the 2nd. During an operation with four strains, i.e., EBHJ2, DP1, DK1 and DPD2794, which are responsive to superoxide damage (EBHJ2 and DP1), hydrogen peroxide (DK1), and DNA damage (DPD2794), the O.D. and bioluminescence of the bacterial cultures inside the system were constant when no chemical was injected. However, with the addition of paraquat, hydrogen peroxide or mitomycin C, the bioluminescent responses of the strains were found to be dose-dependent to different concentrations of these chemicals.

Biological Assay↗