PubMed Health⌕ Search

PubMed · 11254388

Core and surface mutations affect folding kinetics, stability and cooperativity in IL-1 beta: does alteration in buried water play a role?

Abstract

Interleukin-1 beta (IL-1 beta) is a cytokine and a member of the beta-trefoil superfamily of protein structures. An interesting feature in the folding of IL-1 beta, shared with some other members of the same topological family, is the existence of a slow step in folding to the native conformation from a discrete intermediate. Wanting to probe the nature of this slow step in the folding of WT IL-1 beta (tau(1)=45 seconds), we made ten sequence variants of IL-1 beta (L10A, T9Q, T9G, C8S, C8A, N7G, N7D, L6A, R4P, and R4Q), where all mutations are located along strand 1. This strand is not protected from hydrogen exchange until late in folding. Most of the mutations showed little effect on the kinetics of folding for IL-1 beta. However, C8 is clearly involved in both the late and the early steps in folding, while sequence variants at L10 and L6 affect only late events in folding. The value of the slowest relaxation time, tau(1), which is associated with the rate of native protein formation, increased for the refolding of C8S, while C8A, L6A, and L10A showed smaller but systematic increases in the value of tau(1.)For both C8S and C8A, the value of the step associated with formation of the intermediate, tau(2), was independent of denaturant concentration. In addition, mutations in the hydrophobic core (L10A, C8A, C8S, and L6A) and, surprisingly, along the surface (T9G, T9Q, and N7G) alter the stability. The most destabilizing mutations show changes in equilibrium unfolding cooperativity, which is atypical for destabilizing mutations in IL-1 beta. Crystallographic studies indicate that mutations along strand 1 may alter the number of ordered water molecules within the core. Thus, side-chain replacement in this region can disrupt essential main-chain interactions mediated by ordered water contacts in a highly cooperative network of hydrogen bonding.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Covalt, M Roy, P A Jennings. 2001-03-23. Core and surface mutations affect folding kinetics, stability and cooperativity in IL-1 beta: does alteration in buried water play a role?. https://doi.org/10.1006/jmbi.2001.4482

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fluorescence optosensing implemented with sequential injection analysis: a novel strategy for the determination of labetalol.

The coupling of sequential injection analysis and optosensing has been developed for the first time. It has been applied to the determination of labetalol in both pharmaceuticals and urine samples, with the analytical signal (native fluorescence) being monitored directly on sensing zone microbeads. The solid support used was the nonionic silica gel C18, using 20% methanol-water (v:v) as a carrier. By using a 1.5-ml sample volume, we achieved a detection limit of 3.3 ng ml-1. This sensitivity allowed the determination of the compound in urine samples. A recovery study was carried out at the labetalol levels usually found in urine after pharmaceuticals administration, and recovery percentages close to 100% were obtained. The relative standard deviation was 3.4% for 100 ng ml-1 labetalol. No pretreatment was needed for urine samples, only an appropriate dilution, therefore minimizing the time required per sample analysis. In addition, the determination of the analyte was also carried out in one pharmaceutical, with a satisfactory result being obtained.

Flow Injection Analysis↗

Flow-injection solvent extraction without phase separation. Fluorimetric determination of thiamine by the thiochrome method.

Two modes of liquid-liquid extraction in flow-injection systems were compared and applied to the fluorimetric determination of thiamine (Vitamin B(1)). The first included phase segmentation, but fluorescence was measured without phase separation. In this mode, thiamine was detected at concentrations higher than 8 microg/l with a linear application range of 30-2,000 microg/l, an R.S.D. of 1.9% (150 microg/l, n=10) and a sampling frequency of 60/h. In the second mode, a single segment of organic solution was injected into the aqueous stream and fluorescence was also measured without phase separation. Using this mode, concentrations of thiamine higher than 1 microg/l were detected, with a linear application range between 5 and 280 microg/l, an R.S.D. of 2.4% (150 microg/l, n=10) and a sampling frequency of 60/h. The two forms were applied to the analysis of thiamine in pharmaceuticals.

Flow Injection Analysis↗