PubMed Health⌕ Search

PubMed · 11263574

Computer-assisted high-performance liquid chromatography method development with applications to the isolation and analysis of phytoplankton pigments.

Abstract

We used chromatography modeling software to assist in HPLC method development, with the goal of enhancing separations through the exclusive use of gradient time and column temperature. We surveyed nine stationary phases for their utility in pigment purification and natural sample analysis. For purification, a complex algal matrix was separated on an efficient monomeric column, from which partially purified fractions were collected and purified on polymeric columns that exaggerated resolution between pigments of interest. Additionally, we feature an HPLC method that is simple, fast, demonstrates excellent transferability and is ideal for quantitative analysis of pigments in dilute natural water samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Van Heukelem, C S Thomas. 2001-02-23. Computer-assisted high-performance liquid chromatography method development with applications to the isolation and analysis of phytoplankton pigments.. https://doi.org/10.1016/s0378-4347(00)00603-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of gibberellins in fermentation broth produced by Fusarium verticilliodes MTCC 156 by high-performance liquid chromatography tandem mass spectrometry.

A method for the detection of gibberellins produced by Fusarium verticilliodes is described using HPLCMS/MS (HPLC tandem MS). A Hypersil (5 microm) octadecylsilane column with methanol/water as eluent in the ratio 3:1 at a flow rate of 0.5 ml/min was used. In the HPLCMS, GA(3) (gibberellic acid; m / z 346.3) eluted at retention time tr=3.08 min, with the corresponding mass chromatogram having peaks at m / z 346.7 and 328.8 corresponding to the M+ and M+-H2O ions respectively. The ethyl acetate extract from the broth, subjected to HPLCMS analysis under similar conditions, showed a constituent with tr=2.13 min, the mass chromatogram of which exhibited peaks at m / z 348.9 and 331.9 corresponding to the MH+ and MH+-H2O ions respectively. Comparison of the MS and MS/MS results (direct infusion) of an authentic sample of GA3 and the ethyl acetate extract from the broth revealed the formation of reduced GA3 in the broth. The present study, utilizing HPLCMS/MS, describes an improved methodology for the unambiguous determination and estimation of gibberellins from fermentation broth.

Chromatography, High Pressure Liquid↗

A rapid and sensitive method for simultaneous determination of insulin and A21-desamido insulin by high-performance liquid chromatography.

A reversed-phase high-performance liquid chromatography (RP-HPLC) method with UV-detection at room temperature has been developed for the analysis of insulin and its main degradation product, A21-desamido insulin. Octadecylsilica was used as stationary phase and a mixture of water and acetonitrile containing tetrametylammonium hydroxide as eluent. The method produced linear response over the concentration range of 10-100 microg/ml, with an average accuracy of 97.35+/-1.36% as well as average intra- and inter-day variations of 1.29 and 5.24%, respectively. The limits of detection and quantitation of the method were 0.25 and 0.75 microg/ml, respectively. Considering the analysis specifications, the system is suitable for direct analysis of routine formulations and stability studies. By this method human insulin can be separated from its principal degradation product, A21-desamido insulin. Also there is no need for any particular requirement and it is easily available in most of laboratories.

Chromatography, High Pressure Liquid↗

Determination of potential migrants in polycarbonate containers used for microwave ovens by high-performance liquid chromatography with ultraviolet and fluorescence detection.

The determination of several compounds present in a commercial polycarbonate container intended to be used in microwave ovens which could be considered as potential migrants has been carried out by reversed-phase high-performance liquid chromatography (HPLC) with both ultraviolet (UV) and fluorescence detectors. Total dissolution with dichloromethane and polymer reprecipitation with methanol have been used to evaluate 100% potential migration as the worst case. The extract consisted of a complex mixture containing monomers, oligomers, UV stabilizers, antioxidants, degradation products, and other additives. Phenol, Bisphenol A, 2,4-di-tert-butylphenol, Cyasorb UV5411, bis(2-ethylhexylphthalate), Irganox 1076, and Irgafos 168 were identified by both retention times and fluorescence-to-UV ratios. Additional confirmation was achieved by HPLC with diode array detection and gas chromatography-mass spectrometry. Recovery percentages were in the range of 73.8-94.4%, the lowest one being for the antioxidant Irgafos 168 due to its transformation into the phosphate form and 2,4-di-tert-butylphenol. The concentrations of the studied analytes present in the polycarbonate container ranged between 0.9 and 240 microg.g(-)(1). The total dissolution conditions that may affect the final concentration of analytes, mainly Bisphenol A, are discussed.

Chromatography, High Pressure Liquid↗