PubMed Health⌕ Search

PubMed · 11264064

Remote sonographic interpretation using a laser printer network: system performance and diagnostic accuracy in actual clinical practice.

Abstract

OBJECTIVE: The purpose of our study was to evaluate the technical and clinical performance of remote sonographic interpretation using a laser printer network connecting a community-based imaging center and an academic medical center. SUBJECTS AND METHODS: During a 3-month period, 161 consecutive sonographic examinations were performed at a community-based imaging center and all 161 patients were enrolled in the study. Seventy-one (44%) of 161 examinations were interpreted on-site at the community-based imaging center, and 90 (56%) of 161 were transmitted over a T-1 line to an academic medical center where the static images were interpreted remotely. For the purposes of this study, the examination time was defined as the interval from the time the technologist started to scan the patient to the time the patient was dismissed from the radiology department. Examination times were recorded for each patient. Follow-up was available for 92 (57%) of 161 studies. Sensitivity and specificity for studies interpreted at the community-based imaging center and at the academic medical center were calculated. RESULTS: The mean examination time for pelvic sonographic examinations interpreted at the academic medical center (43 min) was significantly longer than for scans interpreted at the community-based imaging center (31 min) (p < 0.01). However, no significant difference was noted in the examination time for abdominal sonography. For all examinations interpreted on-site at the community-based imaging center for which follow-up was available, the sensitivity and specificity were 95% and 100%, respectively. For all examinations interpreted remotely at the academic medical center for which follow-up was available, the sensitivity and specificity were 93% and 90%, respectively. No significant difference was seen in the sensitivity (p = 1.00) or specificity (p = 0.24) of studies interpreted on-site versus remotely. CONCLUSION: Static sonographic images can be interpreted remotely without loss of sensitivity, but with decreased specificity. However, more time must be allotted for performing pelvic sonography when these examinations are to be interpreted remotely.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M P Rosen, T S Mehta, R Bromberg, S L Kelly, D Levine. 2001. Remote sonographic interpretation using a laser printer network: system performance and diagnostic accuracy in actual clinical practice.. https://doi.org/10.2214/ajr.176.4.1760855

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Organization of cutaneous ventrodorsal and rostrocaudal axial lines in the rat hindlimb and trunk in the dorsal horn of the spinal cord.

The somatotopic organization of cutaneous primary afferents projecting to the dorsal horn of the rat spinal cord was investigated. The fluorescent neurotracer, 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiI) was applied to cutaneous incisions made along ventrodorsal axial lines (VDALs) or rostrocaudal axial lines (RCALs) of the trunk and hindlimb. DiI-induced fluorescent zones appeared in laminae I-III of the dorsal horn in the transverse section. Several fluorescent zones appeared at different mediolateral portions after tracer application to VDALs. After tracer was applied to RCALs, a single zone of fluorescence was observed. Serial transverse sections were used to reconstruct fluorescent zones in lamina II and to illustrate the rostrocaudally elongated band-like projection fields in a horizontal plane. In the horizontal plane, the fluorescent zones of VDALs were reconstructed to band-like projection fields. These fields were arranged mediolaterally and extended rostrocaudally for approximately the length of one spinal cord segment or less. The fluorescent zones of RCALs were reconstructed to one band-like projection field. This field extended rostrocaudally over several spinal cord segments. Cutaneous afferents from the ventral median line of the trunk, tail, hindlimb, sole, and ventral side of the digits projected to the medial margin of the dorsal horn. Cutaneous afferents from the dorsal median lines projected to the lateral margin of the dorsal horn. By analyzing the pattern of the body surface regions and the VDALs and RCALs, the central projection fields of body surface regions could be hypothesized, based on the central projection fields of the individual VDAL and RCAL afferents. Thus, we established a detailed dorsal view map of the central projection fields of cutaneous primary afferents.

Abdomen↗

Distinct temporal patterns of macrophage-inflammatory protein-2 and KC chemokine gene expression in surgical injury.

In the present study the regulation of CXC chemokine expression was evaluated in full-thickness abdominal wounds in mice. During the first 24 h after injury, IL-1alphabeta, KC, macrophage-inflammatory protein (MIP)-2, and monocyte chemoattractant protein-1 were the predominant cytokines and chemokines produced; TNF-alpha was not detected. Chemokine mRNA expression and protein secretion occurred in two temporal stages. The first, which reached a maximum at 6 h, was associated with high levels of IL-1alpha and KC and low levels of MIP-2. This stage could be reproduced by intradermal injection of IL-1alpha or IL-1beta and was partially blocked by injection of neutralizing Ab against IL-1alpha but not IL-1beta. In animals depleted of circulating neutrophils, chemokine expression was reduced by nearly 70% during this stage. In the second stage, which peaked at 24 h after injury, modest but significant levels of IL-1beta were detected in association with low levels of KC and high levels of MIP-2. This pattern of chemokine expression could not be mimicked by injection of IL-1alpha or IL-1beta (even with prolonged exposure), although MIP-2 expression could be partially inhibited by intradermal injection of neutralizing Ab against IL-1beta. Surprisingly, neutrophil depletion before injury resulted in sustained high levels of both KC and MIP-2 expression. These observations demonstrate that these two closely related chemokines are under distinct regulatory controls in vivo that are likely to reflect the temporally ordered participation of different cell types and/or extracellular stimuli and inhibitors.

Abdomen↗

Fatigue-related changes in torque output and electromyographic parameters of trunk muscles during isometric axial rotation exertion: an investigation in patients with back pain and in healthy subjects.

STUDY DESIGN: A cross-sectional case-control study. OBJECTIVES: To examine the effect of fatigue on torque output as well as electromyographic frequency and amplitude values of trunk muscles during isometric axial rotation exertion in back pain patients and to compare the results with a matched control group. SUMMARY OF BACKGROUND DATA: Back pain patients exhibited different activation strategies in trunk muscles during the axial rotation exertions. Fatigue changes of abdominal and back muscles during axial rotation exertion have not been examined in patients with back pain. METHODS: Twelve back pain patients and 12 matched controls performed isometric fatiguing axial rotation to both sides at 80% maximum voluntary contraction in a standing position. During the fatiguing exertion, electromyographic changes of rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum, and multifidus were recorded bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were also measured. RESULTS: No difference in the endurance capacity was found between back pain and control groups. At the initial period of the exertion, back pain patients demonstrated a statistical trend (P = 0.058) of greater sagittal coupling torque as well as lower activity of rectus abdominis and multifidus and higher activity in external oblique. During the fatigue process similar changes of coupling torque were demonstrated in both sagittal and coronal planes, but a smaller fatigue rate for right external oblique, increase in median frequency for latissimus dorsi, and lesser increase in activity for back muscles were found in the back pain group compared with the control group. CONCLUSIONS: Alterations in electromyographic activation and fatigue rates of abdominal and back muscles demonstrated during the fatigue process provide insights into the muscle dysfunctions in back pain and may help clinicians to devise more rational treatment strategies.

Abdomen↗