Optimization of beta-quantification methods for high-throughput applications.

Abstract

BACKGROUND: Risk of cardiovascular disease is assessed, in part, by laboratory measurement of the concentrations of several lipoproteins. beta-Quantification is a method of lipoprotein measurement that uses ultracentrifugation to partially separate lipoprotein classes. Although beta-quantification is used largely in clinical and basic research, methods have not been described to allow the analysis of a large number of small-volume specimens with a short turnaround time. We report two variations of the traditional 5-mL method used by the Lipid Research Clinics Program that overcome these shortcomings. METHODS: Two lower-volume modifications of the traditional 5-mL beta-quantification method were developed. The methods used either 1 or 0.23 mL of specimen and required substantially less time for analysis (20 and 6 h, respectively) than the 5-mL method (2.5 days). The goal was to develop ultracentrifugation methods such that the concentration of cholesterol in the bottom fraction, from which LDL-cholesterol concentration is calculated, agreed with the 5-mL method. Fresh serum specimens (n = 45) were analyzed by the three methods to determine comparability of the methods based on the recovery of cholesterol in the bottom fraction after ultracentrifugation. To evaluate intrarun precision, replicate specimens (n = 17) were analyzed in a single run for each method. This experiment also evaluated how quickly the fractions would remix after separation by ultracentrifugation. For the 1-mL method, accuracy of the measurement of LDL- and HDL-cholesterol concentrations and the interrun precision were established by analysis of frozen serum specimens provided by the CDC, which established target values for the pools using reference methods. RESULTS: No clinically significant differences in cholesterol concentrations in the bottom fraction were observed for the 1- and 0.23-mL methods, which had mean biases of 0.8% and 1.5% relative to the 5-mL method, respectively. Intra- and interrun variability was acceptable for each method, e.g., <1.8% for cholesterol in the bottom fraction. Ultracentrifuged specimens were stable for at least 4 h with no evidence of contamination of cholesterol in the bottom fraction. For comparison specimens provided by the CDC, the 1-mL method met the accuracy and precision goals of the National Cholesterol Education Program for the measurement of HDL- and LDL-cholesterol concentrations (goals: total error <13% and <12%, respectively), with total errors of 6.45% and 5.43%, respectively. CONCLUSIONS: Both the 1- and 0.23-mL beta-quantification methods are suitable substitutes for the traditional 5-mL method for use in clinical and basic research for the determination of LDL-cholesterol concentration. Both methods provide much higher throughput and require substantially less specimen volume. The 0.23-mL method can be performed in 1 day, but it is slightly less precise than the 1-mL method. In our laboratory setting, as many as 80 specimens are routinely processed per day using the 1-mL method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T G Cole, C A Ferguson, D W Gibson, W L Nowatzke. 2001. Optimization of beta-quantification methods for high-throughput applications.. https://pubmed.ncbi.nlm.nih.gov/11274022/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A microchip-based multianalyte assay system for the assessment of cardiac risk.

The development of a novel chip-based multianalyte detection system with a cardiac theme is reported. This work follows the initial reports of "electronic taste chips" whereby multiple solution-phase analytes such as acids, bases, metal cations, and biological cofactors were detected and quantitated. The newly fashioned "cardiac chip" exploits a geometry that allows for isolation and entrapment of single polymeric spheres in micromachined pits while providing to each bead the rapid introduction of a series of reagents/washes through microfluidic structures. The combination of these miniaturized components fosters the completion of complex assays with short analysis times using small sample volumes. Optical signals derived from single beads are used to complete immunological tests that yield outstanding assay characteristics. The power and utility of this new methodology is demonstrated here for the simultaneous detection of the cardiac risk factors, C-reactive protein and interleukin-6, in human serum samples. This demonstration represents the first important step toward the development of a useful cardiac chip that targets numerous risk factors concurrently and one that can be customized readily for specific clinical settings.

Blood Chemical Analysis↗