PubMed Health⌕ Search

PubMed · 11288888

Shah convolution Fourier transform detection: multiple-sample injection technique.

Abstract

For the direct measurement of electrophoretic mobility, multiple-point (Shah function) detected, time-domain detector signals were converted into frequency-domain plots by means of Fourier transformation. Multiple sample plugs (up to a maximum of three) were introduced into the separation channel and the resultant time-domain signals were then Fourier-transformed. The multiple-sample injection technique has been successfully demonstrated for a one-component system and a separation. Though the number of fluorescing zones flowing through the illuminated length of the channel is greater than the number of analytes in the solution, Shah convolution Fourier transform detection (SCOFT) is able to identify the number of fluorescent species in the solution based on their migration velocities. The height of the fundamental peak increases as the number of injected sample plugs is increased. More importantly, the signal-to-noise ratio (S/N) is found to be proportional to the number of injected sample plugs. With these findings, the multiple-sample injection technique certainly has got many potential applications in trace analysis. The technique would be equally applicable to other separation techniques (e.g., high-performance liquid chromatography) and detection methods (e.g., absorption, refractive index).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y C Kwok, A Manz. 2001. Shah convolution Fourier transform detection: multiple-sample injection technique.. https://doi.org/10.1002/1522-2683(200101)22%3A2%3C222%3A%3Aaid-elps222%3E3.0.co%3B2-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High-speed analysis of multiplexed short tandem repeats with an electrophoretic microdevice.

We report the development of a robust and effective method for multiplexed short tandem repeat (STR) analysis within a chip-based microdevice. The method uses a laser-induced fluorescence detection system and simultaneously detects three- and four-color multiplexed polymerase chain reaction (PCR) samples. Analyses of the eight combined DNA index system (CODIS) STR loci were performed in 20 min with single-base-pair resolution ranging from 0.75 to 1. A simultaneous analysis of fifteen loci-ladders and a gender marker Amelogenin based on the PowerPlexTM 16 System was achieved in less than 35 min. The system is capable of repetitive operation and may be extended to high-throughput multilane devices that could be readily interfaced to an automated sample loading system.

Electrophoresis↗