A software system for interventional magnetic resonance image-guided prostate brachytherapy.

Abstract

OBJECTIVE: Current prostatic brachytherapy implant procedures use ultrasound imaging for geometric guidance during surgery, with pre-surgical planning based on ultrasound images and post-surgical dosimetry based on computed tomography (CT). This procedure suffers from the poor soft-tissue contrast of ultrasound and CT and problems inherent in the repositioning of the patient at surgery. We have designed and implemented an integrated real-time imaging and treatment-planning software system that combines the superior soft-tissue contrast of magnetic resonance (MR) images with the real-time acquisition of those images for localization, verification, and dosimetric purposes. The system permits the surgeon and patient to complete all phases of treatment in one setting. MATERIALS AND METHODS: We utilize an intra-operative MR unit that permits real-time imaging and stereotactic localization during a surgical procedure. Our software system integrates with the unit and features (i) a calibration schema to calibrate the prostatic surgical implant template within the unit, (ii) full volumetric data acquisition of the prostate, (iii) interactive three-dimensional (3D) treatment planning with volumetric dose evaluation, and (iv) geometric and dosimetric feedback during the surgical procedure. We utilize a software architecture that uses mediators between the abstract data types, or objects. These mediators communicate state changes in individual objects (e.g., a change in a catheter position) to other objects (e.g., a dose-volume histogram) that depend on these changes. A consistent 3D representation of the treatment volumes allows interactive reconstruction of the volumes on arbitrary MR image sections and real-time dose computations. RESULTS: We have successfully implemented the system clinically and have treated 143 patients (as of August 2000). The system supports four clinical phases. The first consists of calibrating the implant template with respect to the patient's anatomy and the MR unit. The second consists of acquiring a complete volumetric MR data set of the prostatic volume. The third consists of delineating the treatment volume (often a sub-volume of the prostate) and the dose-limiting critical volumes. These volumes are used in determining the surgical treatment plan based on catheter and seed placement in the prostate and a dosimetric evaluation of all volumes. The final phase consists of implanting the catheters with the radioactive seeds, where each catheter is imaged and compared to the planned position of the catheter, thus allowing a direct comparison, and possible adjustment, of the implanted versus planned catheter position. CONCLUSIONS: The system is highly interactive, and has great flexibility in its design, maintainability, and clinical practice. The system provides an efficient model to support the surgical procedure. The system significantly improves the diagnostic information provided to the clinician and the treatment planner and the geometric accuracy of the surgical procedure compared to ultrasound procedures. The system allows excellent critical structure sparing, both through interactive placement of the catheters with high geometric accuracy and through the definition of the actual sub-prostatic volumes possible with MR.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H M Kooy, R A Cormack, G Mathiowitz, C Tempany, A V D'Amico. 2000. A software system for interventional magnetic resonance image-guided prostate brachytherapy.. https://doi.org/10.1002/igs.1002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

CT-based postimplant dosimetry of prostate brachytherapy: comparison of 1-mm and 5-mm section CT.

PURPOSE: The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. MATERIALS AND METHODS: A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V(100) (percent of the prostate volume receiving at least the full prescribed dose), and prostate D(90) (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. RESULTS: The mean +/-1 SD postimplant pVol was 20.17 +/- 6.66 cc by 1-mm section CT and 22.24 +/- 8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P < 0.01). The mean postimplant prostate V(100) was 80.44% +/- 7.06% by 1-mm section CT and 77.33% +/- 10.22% by 5-mm section CT. The mean postimplant prostate D(90) was 83.28% +/- 10.81% by 1-mm section CT and 78.60% +/- 15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. CONCLUSION: Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility.

Brachytherapy↗

Long-term results of breast cancer irradiation treatment with low-dose-rate external irradiation.

PURPOSE: The aim of this study was to assess beam therapy with low-dose-rate (LDR) external irradiation in a group of patients with breast cancer. METHODS AND MATERIALS: This trial compared, from 1986 to 1989, patients with advanced breast cancer treated either by conventional fractionation or low-dose-rate (LDR) external radiotherapy (dose-rate 15 mGy/min, 5 sessions of 9 Gy delivered on 5 consecutive days). RESULTS: A total of 21 patients were included in the fractionated therapy arm. At follow-up 15 years after treatment, 7 local recurrences had occurred, 3 patients had died of cancer, 18 patients were alive, 10 were without evidence of disease, and 6 had evidence of disease. A total of 22 patients had been included in the LDR arm of the study. Of these, 11 had received a dose of 45 Gy; thereafter, in view of severe local reactions, the dose was reduced to 35 Gy. There was no local recurrence in patients who had received 45 Gy, although there were 2 local recurrences among the 11 patients after 35 Gy. The sequelae were severe in patients who received 45 Gy but were comparable to those observed in patients treated by fractionated radiotherapy who received 35 Gy. The higher efficacy of tumor control in patients treated by LDR irradiation as well as the lower tolerance of normal tissue are probably related to the lack of repopulation. CONCLUSION: Although the patient numbers in this study are limited, based on our study results we conclude that the data for LDR irradiation are encouraging and that further investigation is warranted.

Brachytherapy↗

Five-year outcome of intraoperative conformal permanent I-125 interstitial implantation for patients with clinically localized prostate cancer.

PURPOSE: To report the 5-year tumor control and toxicity outcomes for patients with localized prostate treated with I-125 permanent implantation using an intraoperative real-time conformal planning technique. METHODS AND MATERIALS: Between January 1998 and June 2002, 367 patients with prostate cancer were treated with I-125 permanent interstitial implantation using a transrectal ultrasound-guided approach. Real-time intraoperative treatment planning which incorporated inverse planning optimization was used. The median follow-up time was 63 months. RESULTS: The median V100 and D90 were 96% and 173 Gy, respectively. In 96% of cases a D90 of >140 Gy was achieved. The median urethral and rectal doses were 100% and 33% of the prescription doses, respectively. The 5-year PSA relapse-free survival outcomes for favorable and intermediate risk patients according to the ASTRO definition were 96% and 89%, respectively. In these patients no dosimetric parameter was identified which influenced the biochemical outcome. Of 38% who developed acute Grade 2 urinary symptoms, 63% had resolution of their symptoms within a median time of 6 months. The incidence of late rectal and urinary Grade 3 or higher toxicities were 1% and 4%, respectively. Seven percent (n = 27) developed late rectal bleeding (Grade 2) and 19% experienced late Grade 2 urinary symptoms. CONCLUSION: Real-time intraoperative planning consistently achieved optimal coverage of the prostate with the prescription dose with concomitant low doses delivered to the urethra and rectum. Biochemical control outcomes were excellent at 5 years and late toxicity was unusual. These data demonstrate that real-time planning methods can consistently and reliably deliver the intended dose distribution to achieve an optimal therapeutic ratio between the target and normal tissue structures.

Brachytherapy↗