PubMed Health⌕ Search

PubMed · 11302037

Screen-based anesthesia simulation with debriefing improves performance in a mannequin-based anesthesia simulator.

Abstract

BACKGROUND: Previous investigations have established the need for improved training for management of anesthetic emergencies. Training with inexpensive screen-based anesthesia simulators may prove to be helpful. PURPOSES: We measured the effectiveness of screen-based simulator training with debriefing on the response to simulated anesthetic critical incidents. METHODS: Thirty-one 1st-year clinical anesthesia residents were randomized into 2 groups. The intervention group handled 10 anesthetic emergencies using the screen-based anesthesia simulator program and received written feedback on their management, whereas the traditional (control) group was asked to study a handout covering the same 10 emergencies. All residents then were evaluated on their management of 4 standardized scenarios in a mannequin-based simulator using a quantitative scoring system. RESULTS: The average point score for the simulator-with-debriefing group was 52.6 +/- 9.9 out of 95 possible points. The traditional group average point score was 43.4 +/- 5.9, p = .004. CONCLUSIONS: Residents who managed anesthetic problems using a screen-based anesthesia simulator handled the emergencies in a mannequin-based anesthesia simulator better than residents who were asked to study a handout covering the same problems. Computer simulations with feedback are effective as a supplement to traditional residency training methods for the management of medical emergencies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H A Schwid, G A Rooke, P Michalowski, B K Ross. 2001. Screen-based anesthesia simulation with debriefing improves performance in a mannequin-based anesthesia simulator.. https://doi.org/10.1207/s15328015tlm1302_4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗