[Shock absorption by intermediate hip prostheses].

Abstract

PURPOSE OF THE STUDY: The bipolar prosthesis was developed in an attempt to alleviate acetabular wear of conventional metallic endoprostheses. The prosthesis was designed to achieve low-friction metal-on-polyethylene inner bearing motion while decreasing shear stress across the acetabular cartilage. Although good clinical results were obtained, the principle of a persistent inner mobility was contested and some authors have assigned the delay of cartilage erosion to the shock absorption capacity of the polyethylene. The present study was focused on assessing the vibration and shock damping effect of metal monoblock and bipolar head prostheses. MATERIAL AND METHODS: The transmission of the shock wave through these two types of prostheses was studied in vitro. The two heads were first tested in a rigid environment to eliminate all external parasite frequencies. The impact excitation was applied with a hammer connected to an oscillometer. A second accelerometer was connected to the prosthesis stem. Shock wave transmission was analyzed. Secondly, the head was tested with a system vibrating in the same order of frequencies as the skeleton, with and without pre-constraint. The frequency response functions were analyzed. RESULTS: For the metallic prosthesis, the frequency of vibration recorded on the femoral stems was in a large frequency range from 0 Hz to 10 KHz. For the bipolar prosthesis, all the high frequencies of the shock wave were eliminated and only shock wave frequencies from 0 to 500 Hz were recorded. In an environmental system vibrating below 100 Hz, the metallic head did not express high frequencies of vibration. The coefficient of shock absorption was not significantly different for the two heads. DISCUSSION: In the first rigid environment, the metallic head did not filter the high frequency components of the shock wave and the bipolar head tended to eliminate high frequency components due to the flattening effect of the impulse load by the polymer. But, the lower leg is not a rigid structure and the musculo-skeletal system vibrates in frequencies below 100 Hz. In similar conditions, the increased shock-absorbing effect of the polyethylene is far more difficult to observe. For the metallic prosthesis, the recorded frequency of vibration also belongs to a small domain of frequency, from 0 Hz to 100 Hz. The range of frequency is similar for the two types of prostheses. CONCLUSION: Even though polyethylene is characterized by a more pronounced damping capacity than metallic materials, in experimental conditions simulating the vibratory characteristics of the human body, the introduction of a high-density polyethylene liner does not afford any additional shock-absorbing effect compared with a metallic head. It cannot explain cartilaginous sparing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Fabeck, J Vantomme, P Y Descamps, C Zekhnini, D Hardy, P Delincé. 2001. [Shock absorption by intermediate hip prostheses].. https://pubmed.ncbi.nlm.nih.gov/11319427/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fixation strength of meniscal repair devices.

The aim of this study was to measure and compare the ultimate failure strengths and cyclic fatigue strengths of currently available meniscal suturing devices. No statistically significant difference in failure load was found between a vertical loop suture (mean 46.3 N), a horizontal mattress suture (52.5 N), the T-fix Device (47.5 N), and the 16-mm (39.2 N) and 13-mm (32.8 N) Bionix Arrow. Statistically inferior results were seen with the 10-mm Bionix Arrow (18.8 N), the S.D. Sorb Stapler (4.3 N), and the 12-mm Arthrex Meniscal Dart (10.5 N) (P<0.01). The Mitek Meniscal Repair System (28.1 N) performed intermediate, with significantly better results than the S.D. Sorb Stapler and the 12-mm Arthrex Dart, but significantly worse than the vertical and horizontal sutures, the T-fix and Bionix 16-mm Device (P<0.01). Cyclic fatigue strength was significantly less for the 10-mm Bionix Arrow, the S.D. Sorb Stapler, and the 12-mm Arthrex Meniscal Dart (P<0.01) compared to all other devices. We conclude that the 13- and 16-mm Bionix Arrow and the T-fix Device have comparable ultimate failure strengths and cyclic fatigue strengths to conventional meniscal suturing techniques. The 10-mm Bionix Arrow, S.D. Sorb Stapler, and the 12-mm Arthrex Meniscal Dart, however, have far inferior failure and cyclic fatigue strengths and their clinical application should be questioned.

Equipment Failure Analysis↗

Measurement of static and vibration-induced phase noise in UHF thin-film resonator (TFR) filters.

Measurements of the static phase noise and vibration sensitivity of thin-film resonator (TFR) filters operating at 640 and 2110 MHz have been made. They show that the short-term frequency instability of the filters is small compared with that induced in the oscillator signal by the sustaining stage amplifier PM (phase modulation) noise. In-oscillator measurement of filter performance under vibration indicates that fractional frequency vibration sensitivities (deltafo/fo) are on the order of several parts in 10(-9)/g. Because the percentage bandwidth and order (number of poles) of the filters was fairly constant, so was the product of the center frequency and group delay. Thus, the fractional frequency vibration sensitivity of the filters can be expressed alternatively as carrier signal phase sensitivity to vibration. The tau-omega0 product for the filters that were tested was on the order of 300 rad, so that the equivalent phase sensitivity to vibration was approximately 1 microrad/g.

Equipment Failure Analysis↗

Output variation from an intensity modulating dynamic collimator.

Intensity modulated radiation therapy (IMRT) offers a method of delivering radiation dose conforming to the shape of targets while minimizing the dose to the surrounding tissue and nearby critical organs. One popular device is the NOMOS MIMiC Collimator coupled to the CORVUS treatment planning system. The MIMiC collimator, mounted on a linac head, opens and closes one or more of its 40 small leaves as determined by the planner while the linac delivers radiation and the gantry rotates. This dynamic IMRT allows the intensity to be modulated yielding a highly conformal dose distribution. However, the dose output becomes a function of the detailed manner in which the leaves open and close, since the opening and closing are not instantaneous. We investigate the effect of switch rates and delay in the open/close events on the output profiles. The output is enhanced as the switch rate increases. The enhancement factor at any point of measurement is dependent on its distance from the central plane. We interpret these variations in terms of a simple model, which includes the effect of leaf travel time during the process of opening and closing. We also include the time delay in establishing the specified pressure in the pneumonic device, which controls the opening and closing of the leaves. The information presented here offers a means for incorporating these output changes into the planning system. This may avoid the current situation where many patient plans need to be renormalized based on the actual measurement taken during the delivery of the specified intensity pattern to a phantom.

Equipment Failure Analysis↗